18.05.2014 Views

SunTouch® - Pentair

SunTouch® - Pentair

SunTouch® - Pentair

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

31<br />

Pump Menu (12/14) (Continued)<br />

IntelliFlo ® VS pump (Continued)<br />

From the IntelliFlo VS menu you can assign an auxiliary circuits to control four different pump speeds. The<br />

pump speed can be adjusted from 400 to 3450 RPM in increments of 10 RPM. For more information about the<br />

IntelliFlo VS, refer to the IntelliFlo VS Installation and User’s Guide (P/N 357269).<br />

To assign up eight (8) pump speeds and circuits for the IntelliFlo VS3050 pump:<br />

Main Menu 12/14<br />

Pumps<br />

Pump Type<br />

[INTELLIFLO VS ]<br />

Pumps Parameters<br />

Menu: SPEEDS<br />

Assign Speeds<br />

1 - RPM: 3450<br />

Circuit Setup<br />

1 - [ SPA ]<br />

Pumps Parameters<br />

Menu: PRIMING<br />

Priming Params<br />

Time: 5<br />

Priming Params<br />

Speed: 1000<br />

Pumps Parameters<br />

Menu: STATUS<br />

RPM: 1500<br />

75 W<br />

Status: NORMAL<br />

Menu button: Select the Pumps 12/14 menu.<br />

Right button: Press the button to view the type of pump to select.<br />

Up/Down buttons: Select IntelliFlo VS. Press Right button again to select.<br />

Press Up/Down buttons to view the pump parameters menus: SPEEDS,<br />

PRIMING or STATUS. Press Right button to select. Press the Right button<br />

again to ASSIGN SPEEDS (RPM) setting. Press Up/Down buttons set the pump<br />

speed. Pump speeds can be set from 400 to 3450 RPM in increments of 10 RPM.<br />

The default speed for each circuit is the same as the four speed buttons on the<br />

IntelliFlo VS control panel. The preset speed which corresponds to each of the four<br />

buttons on the pump are: 1 button 750 RPM, 2 button 1500 RPM, 3 button 2350<br />

RPM, and 4 button 3110 RPM.<br />

Press Right button to ASSIGN CIRCUIT for the pump. Press Up/Down buttons<br />

to view the circuits for the first of eight pump circuits: [NONE, SPA, POOL, AUX 1,<br />

AUX 2, AUX 3, FEATURE 1 - 4, SOLAR, HEATER, FREEZE, POOL/SPA, and<br />

SOLAR/HT (solar/heater)]. Press Right button to select the circuit. Note:<br />

Selecting “Pool/Spa” or “Solar/HT” combines several circuits into the same<br />

pump speed for pool and spa or for solar and heater combination systems.<br />

Normally this would require programming two separate pump speeds for each<br />

function. Using one of these selections, free-up one of the four pump speed for<br />

other uses.<br />

Right button: Press this button to continue to assign pump SPEEDS and<br />

CIRCUITS. You can assign up to eight (8) pump speeds and circuits.<br />

When finished assigning speeds and circuits, press the Right button until SPEEDS is<br />

displayed, then press the Up/Down buttons and select PRIMING. Press Right<br />

button to select Priming Params Time. Press the Up/Down buttons to set the<br />

priming time (0 to 10 minutes). When finished, Press Right button to select Priming<br />

Params Speed. Press the Up/Down buttons to set the priming speed (4000 - 3450<br />

RPM). To select STATUS, press the Right button three (3) time, then press the<br />

Up/Down button to select STATUS. Press the Right button to view the current<br />

RPMs and operating Watts. Press the button again to view the current pump<br />

communication status.<br />

Left button: Press the Left button to return to the main status screen.<br />

SunTouch Solar, Pool and Spa Control System Installation and User’s Guide

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!