71<br />

Temperature vs. Resistance Data<br />

SunTouch systems use 10k Ωαττ thermistor sensors. When the solar sensor is disconnected from the<br />

SunTouch system, the sensor will read 10k Ω at 77º F (25ºC). Refer to the following table for the resistance at<br />

other temperatures. An accurate reading should give a temperature setting that is accurate<br />

to ±0.2º C from 0 to 70 º C.<br />

Temperature Resistance Temperature<br />

Resistance<br />

o<br />

C o<br />

F Ω o<br />

C o<br />

F Ω<br />

-26 -15 139,300 16 60 15,310<br />

-25 -13 130,300 18 65 13,480<br />

-23 -10 118,000 21 70 11,880<br />

-21 -5 100,200 24 75 10,500<br />

-20 -4 97,000 25 77 10,000<br />

-18 0 85,350 27 80 9,298<br />

-15 5 72,910 29 85 8,250<br />

-12 10 62,480 30 86 8,056<br />

-9 15 53,640 32 90 7,331<br />

-10 14 55,300 35 95 6,530<br />

-7 20 46,230 38 100 5,826<br />

-5 23 42,300 40 104 5,326<br />

-4 25 39,910 41 105 5,209<br />

-1 30 34,560 43 110 4,663<br />

0 32 32,600 45 113 4,367<br />

2 35 30,000 49 120 3,757<br />

4.7 40 26,100 50 122 3,602<br />

5 41 25,400 52 125 3,381<br />

7 45 22,760 54 130 3,047<br />

10 50 19,900 55 131 2,985<br />

13 55 17,440 57 135 2,750<br />

15 59 15,700<br />

SunTouch Solar, Pool and Spa Control System Installation and User’s Guide