SunTouch® - Pentair
SunTouch® - Pentair
SunTouch® - Pentair
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
72<br />
IntelliChlor Error Messages<br />
IntelliChlor status and error messages are displayed in the “Chlorinator” menu (see page 32). Use the<br />
following information to resolve IntelliChlor system problems. To access the IntelliChlor menu, press<br />
Menu > Diagnostics > Chlorinator.<br />
Status<br />
Message<br />
OK-NO ERRORS<br />
SUPER CHLORINATE<br />
COM LINK ERROR<br />
CHECK FLOW/PCB<br />
Possible<br />
Cause<br />
IntelliChlor normal<br />
operating mode.<br />
IntelliChlor is in "Super<br />
Chlorination" mode for 24<br />
hours.<br />
IntelliChlor communication<br />
error with SunTouch<br />
motherboard.<br />
Check IntelliChlor<br />
electrolytic cell.<br />
Solution<br />
N/A<br />
IntelliChlor is in “Super Chlorination mode (see page 32<br />
for details)<br />
Check cable from IntelliChlor to SunTouch motherboard.<br />
Refer to IntelliChlor User’s Guide troubleshooting<br />
information.<br />
L OW SALT<br />
A dd salt to pool water.<br />
The water salt level is between 2500 ppm and 2900 ppm.<br />
The IntelliChlor will continue to produce chlorine at a<br />
reduced level. See IntelliChlor User's Guide for details.<br />
V ERY LOW SALT<br />
Not<br />
enough salt in pool.<br />
The water salt level has fallen below 2500 parts per<br />
million (ppm). IntelliChlor will not produce chlorine until<br />
additional salt is added manually. See IntelliChlor User's<br />
Guide for details.<br />
HIGH CURRENT<br />
CLEAN CELL!!<br />
LOW VOLTAGE<br />
Check IntelliChlor<br />
electrolytic cell.<br />
Cell has calcium build up<br />
and requires cleaning.<br />
Check IntelliChlor<br />
electrolytic cell.<br />
Check IntelliChlor electrolytic cell controller. Refer to<br />
IntelliChlor User’s Guide troubleshooting information.<br />
Cell has calcium build up and requires cleaning. Refer to<br />
IntelliChlor User’s Guide for cleaning instructions.<br />
Refer to IntelliChlor User’s Guide troubleshooting<br />
information.<br />
System Problem Diagnosis<br />
Use the following information to resolve system problems.<br />
Problem: SunTouch LCD fails to operate.<br />
Symptom<br />
SunTouch enclosure has no<br />
power - (screen, blank, no LEDs,<br />
buttons not working).<br />
SunTouch control panel LCD<br />
lights up, but fails to operate<br />
correctly.<br />
Possible<br />
Cause<br />
Bad wiring run from<br />
Outdoor Control<br />
Panel/motherboard in the<br />
Load Center.<br />
Defective<br />
Cable/wiring<br />
Solution<br />
Verify cable and ensure no connections are broken. In<br />
some cases a wire is broken under the insulation. The<br />
two center wires of the four conductor cable are suspect<br />
(Green and Yellow)<br />
Verify<br />
cable<br />
and ensure no connections are broken. In<br />
some cases a wire is broken under the insulation. The<br />
two center wires of the four conductor cable are suspect<br />
(Green and Yellow)<br />
SunTouch Solar, Pool and Spa Control System Installation and User’s Guide