Pool/Spa Mode Menus<br />
The following describes the 14 “Pool/Spa mode” menus. Displayed on the Main Menu screen is the menu<br />
description and the menu number (1/14).<br />
Circuit On/Off Menu (1/14)<br />
Use the “Circuit On/Off” menu feature to manually switch ON/OFF the pool filter pump, auxiliary<br />
circuits (AUX 1-3) and feature circuits (FT. 1-4). Switching circuits on or off will override any<br />
programmed schedules that might already be assigned to these circuits. For more information about schedules,<br />
see “Schedules Menu” on page 17.<br />
POOL FILTER PUMP ON/OFF: Use the “Circuit On/Off” Pool setting, to manually switch the pool filter pump<br />
relay on or off. When the pool filter pump switched on, the valve actuator will rotate to isolate the pool water<br />
from the spa water, and switch the heater on (if enabled in the “Heat” menu). When this circuit relay is<br />
switched on manually, it remains on until either you switch it off manually or the default 12 hours has elapsed.<br />
The system default 12 hours can be changed from 1 to 23 hours (see “Circuit Timeout” page 24). For<br />
example, if the filter pump is scheduled to automatically run from 9:00 AM to 5:00 PM daily, then the filter<br />
pump is switched on manually at 9:00 PM, it will run continuously until the next day at 5:00 PM then switch<br />
off. The schedule will then continue from then on. The top display line on the main status screen will<br />
alternately display the current water temperature and the current air temperature (if the air sensor is enable,<br />
see page 24 for details). If the pool filter pump is on, and the spa is switched on using the Up arrow button, the<br />
main status screen will alternately display the current water temperature between “Pool” and “Spa” mode. For<br />
HI-TEMP, LO-TEMP controls (SunTouch single body system), see page 40.<br />
Main Menu 1/14<br />
Circuit On/Off<br />
Circuit On/Off<br />
Pool: ON<br />
Pool 77°F / 79°F<br />
9:45 AM HEATER<br />
Menu button > Right arrow button: Select Circuit On/Off (1/14).<br />
Up/Down arrow button: Press the Up or Down button to toggle the POOL pump<br />
circuit ON or OFF. After switching the Pool filter pump ON, the main status screen<br />
displays the current pool water temperature. To adjust the set point temperature, use<br />
the Left and Right arrow buttons.<br />
Right arrow button: Select the “Circuit On/Off” Pool On/Off setting. Use this<br />
function to manually switch the pool filter pump on or off.<br />
Note: The Solar auxiliary relay (Valve C) on the SunTouch motherboard can<br />
operate a solar booster pump which will switch on when the filter pump is<br />
running. Solar heat must also be available and the water must be below the set<br />
point temperature setting. For more information, see “Solar Menu” on page 20.<br />
Left arrow button: Press the Left button to return to the main status screen.<br />
AUX 1, AUX 2: Use this feature to manually switch the auxiliary relay output circuit on or off. These auxiliary<br />
circuits can be assigned to operate the pool and spa system valves, lights and other equipment. When the<br />
AUX 1 or AUX 2 circuit relay is switched on manually, it remains on until either you switch it off manually,<br />
the default 12 hours has elapsed.<br />
Main Menu 1/14<br />
Circuit On/Off<br />
Circuit On/Of<br />
AUX 2: ON<br />
AIR 71°F<br />
11: 51AM AUX D3<br />
Menu button > Right arrow button: Select the Circuit On/Off 1/14 menu to<br />
manually switch AUX 1, AUX 2 relay ON or OFF.<br />
Right arrow button: Press the Right arrow button until AUX 1, AUX 2, or AUX 3<br />
is displayed.<br />
Up/Down arrow button: Press the Up/Down arrow button to toggle the AUX<br />
circuit on or off.<br />
Left arrow button: Press the Left button to return to the main status screen.<br />
AUX 3: AUX 3 circuit can be used as an extra assignment to control and electric heater, pump speeds or a<br />
valve actuator (see page 26 for details). For example, AUX 3 can be assigned to control the high speed<br />
function of a 2-Speed pump or one of the four speeds of the IntelliFlo VS. The pump speed control can be<br />
selected/activated via a scheduled program or switched on/off manually. You can also assign a button on the<br />
four-function QuickTouch wireless remote (optional equipment) to control the high-speed pump function.<br />
Continue on next page.<br />