Connecting SunTouch to a Gas Heater<br />
The SunTouch motherboard provides a set of low voltage dry contacts that can be connected to most gas<br />
heaters and heat pumps. Refer to your heater documentation for specific wiring instructions for connecting the<br />
heater to an external control (typically using a two-wire remote control connection).<br />
Note: SunTouch motherboard heater screw terminals (J12) can be used for high voltage connection not<br />
higher than 24 VAC or VDC current for electric heaters or heat pumps.<br />
Connecting to a standard heater<br />
The following installation instructions are for gas heaters and heat pumps with low voltage thermostats.<br />
To connect a standard heater to SunTouch:<br />
1. Switch the power OFF to the heater.<br />
2. Run a two-conductor cable from the heater thermostat area to the low voltage raceway to the<br />
motherboard in the SunTouch Power Center. Use 105° C temperature rated wire for connection to<br />
the heater. When connecting wires inside the heater, be cautious of HOT internal parts of the heater.<br />
Refer to the heater owners manual for the manufacturer’s recommendations for the minimum<br />
temperature rating for wires.<br />
3. Strip the conductors ¼ in. Insert the wires into the GAS HEATER two-screw terminals (J12) on the<br />
motherboard. For SunTouch motherboard wiring connections, refer to “SunTouch Motherboard<br />
Connections,” on page 53.<br />
4. At the heater, connect the wires in accordance with heater manufacturer’s instructions. For older<br />
heaters without instructions for remote operation, connect the wires to the “Fireman’s Switch”<br />
connections in series with the thermostat, pressure switch, and other safety switches.<br />
5. Do NOT disconnect or wire around the thermostat, pressure switch, high limit switch, or other safety<br />
devices.<br />
6. Switch ON the main power switch of the heater. Note, SunTouch does not control the AC power to<br />
the heater.<br />
7. Set the heater thermostat to the maximum hottest setting.<br />
8. From the SunTouch menu (see page 26): Goto Main Menu 10/14 “Circ Functions” and assign<br />
AUX 1 or AUX 2 to “HEATER.”<br />
Connecting to a <strong>Pentair</strong> Water Pool and Spa ® MiniMax ® , MasterTemp® Gas Heater<br />
To connect a MiniMax, or MasterTemp heater to the SunTouch power center:<br />
1. Switch the power OFF to the heater.<br />
2. Remove the factory installed jumper from the “Ext Switch” connector.<br />
3. Connect the two-wire cable from J12 on the SunTouch motherboard to the “Ext Switch” terminal.<br />
CAUTION: Be sure that the wires from the heater to the SunTouch Power Center are not near<br />
or touching any line voltage wires in the heater. Failure to follow these instructions may cause<br />
the heater to malfunction.<br />
4. Set the Power (Thermostat Select) switch to either “Pool” or “Spa.”<br />
5. Set the “Pool” and “Spa” thermostats to their maximum position.<br />
6. From the SunTouch menu (see page 26): Goto Main Menu 10/14 “Circ Functions” and assign<br />
AUX 1 or AUX 2 to “HEATER.”<br />