18.05.2014 Views

SunTouch® - Pentair

SunTouch® - Pentair

SunTouch® - Pentair

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

62<br />

Connecting SunTouch to a Gas Heater<br />

The SunTouch motherboard provides a set of low voltage dry contacts that can be connected to most gas<br />

heaters and heat pumps. Refer to your heater documentation for specific wiring instructions for connecting the<br />

heater to an external control (typically using a two-wire remote control connection).<br />

Note: SunTouch motherboard heater screw terminals (J12) can be used for high voltage connection not<br />

higher than 24 VAC or VDC current for electric heaters or heat pumps.<br />

Connecting to a standard heater<br />

The following installation instructions are for gas heaters and heat pumps with low voltage thermostats.<br />

To connect a standard heater to SunTouch:<br />

1. Switch the power OFF to the heater.<br />

2. Run a two-conductor cable from the heater thermostat area to the low voltage raceway to the<br />

motherboard in the SunTouch Power Center. Use 105° C temperature rated wire for connection to<br />

the heater. When connecting wires inside the heater, be cautious of HOT internal parts of the heater.<br />

Refer to the heater owners manual for the manufacturer’s recommendations for the minimum<br />

temperature rating for wires.<br />

3. Strip the conductors ¼ in. Insert the wires into the GAS HEATER two-screw terminals (J12) on the<br />

motherboard. For SunTouch motherboard wiring connections, refer to “SunTouch Motherboard<br />

Connections,” on page 53.<br />

4. At the heater, connect the wires in accordance with heater manufacturer’s instructions. For older<br />

heaters without instructions for remote operation, connect the wires to the “Fireman’s Switch”<br />

connections in series with the thermostat, pressure switch, and other safety switches.<br />

5. Do NOT disconnect or wire around the thermostat, pressure switch, high limit switch, or other safety<br />

devices.<br />

6. Switch ON the main power switch of the heater. Note, SunTouch does not control the AC power to<br />

the heater.<br />

7. Set the heater thermostat to the maximum hottest setting.<br />

8. From the SunTouch menu (see page 26): Goto Main Menu 10/14 “Circ Functions” and assign<br />

AUX 1 or AUX 2 to “HEATER.”<br />

Connecting to a <strong>Pentair</strong> Water Pool and Spa ® MiniMax ® , MasterTemp® Gas Heater<br />

To connect a MiniMax, or MasterTemp heater to the SunTouch power center:<br />

1. Switch the power OFF to the heater.<br />

2. Remove the factory installed jumper from the “Ext Switch” connector.<br />

3. Connect the two-wire cable from J12 on the SunTouch motherboard to the “Ext Switch” terminal.<br />

CAUTION: Be sure that the wires from the heater to the SunTouch Power Center are not near<br />

or touching any line voltage wires in the heater. Failure to follow these instructions may cause<br />

the heater to malfunction.<br />

4. Set the Power (Thermostat Select) switch to either “Pool” or “Spa.”<br />

5. Set the “Pool” and “Spa” thermostats to their maximum position.<br />

6. From the SunTouch menu (see page 26): Goto Main Menu 10/14 “Circ Functions” and assign<br />

AUX 1 or AUX 2 to “HEATER.”<br />