59<br />

Installing relays (Continued)<br />

Standard relay (Location 3): Position the relay (coil facing upward) on top of the mounting studs.<br />

Align the relay flanges with the screw holes. Using a 1/4 in nut driver, secure the relay in place with<br />

the two retaining screw.<br />

Mounting studs for<br />

relay screws<br />

2-Speed Relay (location 3): Position the relay bracket on top of the mounting studs. Align the<br />

bracket with screw holes. Using a 1/4 nut driver, secure the bracket with the two retaining screws.<br />

Insert the relay (coil facing to the right-side) into the relay bracket and snap in place.<br />

Mounting studs for<br />

relay screws<br />

Bracket<br />

Insert 2-Speed<br />

relay into<br />

bracket<br />

2. Route the relay cable into the slot between the low voltage compartment and the transformer<br />

compartment to the SunTouch motherboard.<br />

Note: If there is an Emergency Shut-Off Switch (ESO) circuit board installed in the SunTouch<br />

Power Center, connect the relay wires to the ESO circuit board. For more information, see<br />

“Emergency Shut-Off Switch Installation,” on page 73.<br />

3. Connect the relay plugs onto the PUMP, AUX 1 or AUX 2 two-pin socket on the motherboard.<br />

2-SPEED RELAY CONNECTION: The 2-Speed relay cable plug is connected to AUX 3 which controls the<br />

pump’s high speed output. The AUX 3 circuit output can only be used to control the following:<br />

2-Speed pump relay, one of the four speeds (RPM) of an IntelliFlo VS pump or the flow rate (GPM)<br />

of an IntelliFlo VF pump. For installation and operation information, refer to the Two-Speed Relay<br />

User’s Guide (P/N 520210).<br />

Note: The IntelliChlor and IntelliFlo pump does not require a relay connection, it connects to<br />

the COM Port (J11) connector on the SunTouch notherboard.<br />

Note: For SunTouch motherboard wiring connections, refer to “SunTouch Motherboard<br />

Connections,” on page 53.<br />

SunTouch Solar, Pool and Spa Control System Installation and User’s Guide