IntelliChlor Menu (13/14): Status and Error Messages<br />
If an error alert, or warning is detected by IntelliChlor, the error message will be displayed on the SunTouch<br />
control panel screen. All status and error messages can be viewed from the IntelliChlor menu. For<br />
troubleshooting information, refer to the IntelliChlor Electronic Chlorine Generator User’s Guide (P/N 520589).<br />
To view the IntelliChlor status and error messages:<br />
Main Menu 13/14<br />
IntelliChlor<br />
Salt: 3200 ppm<br />
[OK - NO ERRORS]<br />
Menu button: Select the IntelliChlor menu.<br />
Right button: Press the button until the Salt status screen is displayed.<br />
Displays the current IntelliChlor chlorination system status.<br />
Left/Right button: Press the Left or Right button to return to the main status<br />
screen.<br />
IntelliChlor status and error messages:<br />
SALT LEVEL: Displays the current salt level. Values from 0 to 12750 ppm in 50 ppm<br />
increments.<br />
IntelliChlor Status and Error messages:<br />
SUPER CHLORINATE: IntelliChlor is in Super Chlorination mode. For information<br />
COM LINK ERROR: Check cable from IntelliChlor to SunTouch motherboard.<br />
Check FLOW/PCB: Check IntelliChlor electrolytic cell controller. Refer to IntelliChlor<br />
User’s Guide troubleshooting information.<br />
LOW SALT: Add salt to pool water. The water salt level is between 2500 ppm and<br />
2950 ppm. The IntelliChlor will continue to produce chlorine at a reduced level.<br />
VERY LOW SALT: Not enough salt in pool. The water salt level has fallen below 2500<br />
parts per million (ppm). IntelliChlor will not produce chlorine until additional salt is<br />
added manually.<br />
HIGH CURRENT: Check IntelliChlor electrolytic cell controller. Refer to IntelliChlor<br />
User’s Guide troubleshooting information.<br />
CLEAN CELL!!: Cell has calcium build up and requires cleaning. Refer to IntelliChlor<br />
User’s Guide for cleaning instructions.<br />
LOW VOLTAGE: Check IntelliChlor electrolytic cell controller. Refer to IntelliChlor<br />
User’s Guide troubleshooting information.<br />
OK - NO ERRORS: IntelliChlor is in normal operating mode.<br />
About Super Chlorination: The Super Chlorination feature is used to introduce large amounts of chlorine<br />
into the pool water if there has been heavy rain fall, many bathers in the pool, cloudy water conditions, etc.<br />
When Super Chlorination is enabled, the system will switch on the filter pump, set the pool/spa valves to the<br />
correct position, and set the IntelliChlor chlorine generator to maximum output. This process continues for 24<br />
hours. At the end of the Super Chlorination process, the system will return to normal operation. It is possible to<br />
manually stop the Super Chlorination process and switch off the filter pump in the “Circuit On/Off” menu<br />
(see page 13). When the filter pump is switched on again, the Super Chlorine process will resume for the<br />