37<br />

IntelliChlor Menu (13/14): Status and Error Messages<br />

If an error alert, or warning is detected by IntelliChlor, the error message will be displayed on the SunTouch<br />

control panel screen. All status and error messages can be viewed from the IntelliChlor menu. For<br />

troubleshooting information, refer to the IntelliChlor Electronic Chlorine Generator User’s Guide (P/N 520589).<br />

To view the IntelliChlor status and error messages:<br />

Main Menu 13/14<br />

IntelliChlor<br />

Salt: 3200 ppm<br />

[OK - NO ERRORS]<br />

Menu button: Select the IntelliChlor menu.<br />

Right button: Press the button until the Salt status screen is displayed.<br />

Displays the current IntelliChlor chlorination system status.<br />

Left/Right button: Press the Left or Right button to return to the main status<br />

screen.<br />

IntelliChlor status and error messages:<br />

SALT LEVEL: Displays the current salt level. Values from 0 to 12750 ppm in 50 ppm<br />

increments.<br />

IntelliChlor Status and Error messages:<br />

SUPER CHLORINATE: IntelliChlor is in Super Chlorination mode. For information<br />

COM LINK ERROR: Check cable from IntelliChlor to SunTouch motherboard.<br />

Check FLOW/PCB: Check IntelliChlor electrolytic cell controller. Refer to IntelliChlor<br />

User’s Guide troubleshooting information.<br />

LOW SALT: Add salt to pool water. The water salt level is between 2500 ppm and<br />

2950 ppm. The IntelliChlor will continue to produce chlorine at a reduced level.<br />

VERY LOW SALT: Not enough salt in pool. The water salt level has fallen below 2500<br />

parts per million (ppm). IntelliChlor will not produce chlorine until additional salt is<br />

added manually.<br />

HIGH CURRENT: Check IntelliChlor electrolytic cell controller. Refer to IntelliChlor<br />

User’s Guide troubleshooting information.<br />

CLEAN CELL!!: Cell has calcium build up and requires cleaning. Refer to IntelliChlor<br />

User’s Guide for cleaning instructions.<br />

LOW VOLTAGE: Check IntelliChlor electrolytic cell controller. Refer to IntelliChlor<br />

User’s Guide troubleshooting information.<br />

OK - NO ERRORS: IntelliChlor is in normal operating mode.<br />

About Super Chlorination: The Super Chlorination feature is used to introduce large amounts of chlorine<br />

into the pool water if there has been heavy rain fall, many bathers in the pool, cloudy water conditions, etc.<br />

When Super Chlorination is enabled, the system will switch on the filter pump, set the pool/spa valves to the<br />

correct position, and set the IntelliChlor chlorine generator to maximum output. This process continues for 24<br />

hours. At the end of the Super Chlorination process, the system will return to normal operation. It is possible to<br />

manually stop the Super Chlorination process and switch off the filter pump in the “Circuit On/Off” menu<br />

(see page 13). When the filter pump is switched on again, the Super Chlorine process will resume for the<br />

duration of time that is left.<br />