SunTouch® - Pentair
SunTouch® - Pentair
SunTouch® - Pentair
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
75<br />
Wiring SunTouch to the IntelliChlor Salt Chlorine Generator<br />
Be sure to check the wire color and function of the IntelliChlor salt chlorine generator before connecting it to<br />
the SunTouch COM port on the motherboard. See the wiring table below for the pin configuration.<br />
Failure to wire the salt chlorine generator properly can permanently damage the SunTouch system or chlorine<br />
generator. For more information about wiring IntelliChlor to the SunTouch power center, see page 79. See<br />
“IntelliChlor” Main Menu (13/14) on page 33 for setup information.<br />
IntelliChlor AC Wiring Instructions: When using an IntelliChlor salt chlorine generator with the<br />
SunTouch system, the IntelliChlor AC power center wires must be connected to the PUMP SIDE OF THE<br />
MAIN FILTER PUMP RELAY (LOAD SIDE) located in the SunTouch power center. This ensures the<br />
IntelliChlor cell produces chlorine only when the main filter pump is on (see page 73 and 74).<br />
Wiring Description<br />
(SunTouch COM Port to IntelliChlor Power Center COM Port)<br />
SunTouch COM Port<br />
color connection<br />
wiring<br />
Descripion<br />
IntelliChlor Power Center COM<br />
Port<br />
RED<br />
YELLOW<br />
GREEN<br />
+ 15 VDC<br />
RED<br />
+ DAT A YELLOW<br />
- DAT A<br />
GREEN<br />
BLACK<br />
GROUND<br />
BLACK<br />
Wiring Description<br />
(Hayward® or Jandy® Load Center COM Port)<br />
Hayward® or Jandy® Load<br />
Center COM port wiring<br />
color connection<br />
Descripion<br />
IntelliChlor Salt Chlorine<br />
Generator<br />
RED<br />
YELLOW<br />
GREEN<br />
+ 15 VDC<br />
RED<br />
+ DAT A BLACK<br />
- DAT A<br />
YELLOW<br />
BLACK<br />
GROUND<br />
GREEN<br />
SunTouch Solar, Pool and Spa Control System Installation and User’s Guide