Description of Each Item<br />
RF Control<br />
Item Description The range of the set code. Default<br />
Antenna Power Power (dBm) of each<br />
antenna (from 1 to 4)<br />
10.0 to 32.0<br />
(Truncate by 0.5.<br />
Ex. 10.3 is truncated to 10.0<br />
Every antenna:<br />
30.5<br />
Session<br />
Session number of Gen2<br />
protocol.<br />
(set for Multi sequence and<br />
Single sequence respectively)<br />
and 10.8 is truncated to 10.5.)<br />
0 / 1 / 2 / 3 SOC/MOC - 0<br />
SRP/MRP - 2<br />
Mode Communication mode Normal / DRM Normal<br />
EPC word len EPC word length 0 to 32 (step 1) 0<br />
Filtering<br />
Item Description The range of the set code. Default<br />
Condition Selection Determines filtering<br />
None / 1 / 2 / 1 and 2 / (None)<br />
condition<br />
1 or 2<br />
Condition 1 Set value of the Condition 1<br />
Bank Communication data bit 0 to 3<br />
(None)<br />
length<br />
(including threshold values)<br />
Pointer Comparison start point 0 to 255<br />
(None)<br />
(including threshold values).<br />
Length Comparison bit length 1 to 255<br />
(None)<br />
(including threshold values)<br />
Data Comparison data Data length/ more than 1 or<br />
more and 64 or less<br />
(None)<br />
Condition 2 Set value of the Condition 2<br />
Bank Communication data bit<br />
length<br />
0 to 3<br />
(including threshold values)<br />
Pointer Comparison start point 0 to 255<br />
(including threshold values).<br />
Length Comparison bit length 1 to 255<br />
(including threshold values)<br />
Data Comparison data Hex string whose length is 1<br />
or more and 64 or less<br />
(None)<br />
(None)<br />
(None)<br />
(None)<br />
Smoothing<br />
Item Description The range of the set code. Default<br />
Smoothing Buffer Prevents rereading 0 to 999<br />
0<br />
(including threshold values)<br />
Omit Response Omits response for no tag Disable / Enable Disable<br />