Description of Each Item<br />

RF Control<br />

Item Description The range of the set code. Default<br />

Antenna Power Power (dBm) of each<br />

antenna (from 1 to 4)<br />

10.0 to 32.0<br />

(Truncate by 0.5.<br />

Ex. 10.3 is truncated to 10.0<br />

Every antenna:<br />

30.5<br />

Session<br />

Session number of Gen2<br />

protocol.<br />

(set for Multi sequence and<br />

Single sequence respectively)<br />

and 10.8 is truncated to 10.5.)<br />

0 / 1 / 2 / 3 SOC/MOC - 0<br />

SRP/MRP - 2<br />

Mode Communication mode Normal / DRM Normal<br />

EPC word len EPC word length 0 to 32 (step 1) 0<br />

Filtering<br />

Item Description The range of the set code. Default<br />

Condition Selection Determines filtering<br />

None / 1 / 2 / 1 and 2 / (None)<br />

condition<br />

1 or 2<br />

Condition 1 Set value of the Condition 1<br />

Bank Communication data bit 0 to 3<br />

(None)<br />

length<br />

(including threshold values)<br />

Pointer Comparison start point 0 to 255<br />

(None)<br />

(including threshold values).<br />

Length Comparison bit length 1 to 255<br />

(None)<br />

(including threshold values)<br />

Data Comparison data Data length/ more than 1 or<br />

more and 64 or less<br />

(None)<br />

Condition 2 Set value of the Condition 2<br />

Bank Communication data bit<br />

length<br />

0 to 3<br />

(including threshold values)<br />

Pointer Comparison start point 0 to 255<br />

(including threshold values).<br />

Length Comparison bit length 1 to 255<br />

(including threshold values)<br />

Data Comparison data Hex string whose length is 1<br />

or more and 64 or less<br />

(None)<br />

(None)<br />

(None)<br />

(None)<br />

Smoothing<br />

Item Description The range of the set code. Default<br />

Smoothing Buffer Prevents rereading 0 to 999<br />

0<br />

(including threshold values)<br />

Omit Response Omits response for no tag Disable / Enable Disable<br />