2.3.3 Self-Operation<br />

This function enables the reader to start some works, judge, and output the results without instruction of<br />

host by combining followings; registering command, setting reader status output, and setting communication<br />

result judgment.<br />

(1) Command entry<br />

Commands can be registered in Startup and 4 digital inputs respectively.<br />

Available conditions<br />

Executing timing<br />

Reader: Startup<br />

Power up or TCP/IP connection<br />

The rising edge of input #1 signal.<br />

The rising edge of input #2 signal.<br />

The rising edge of input #3 signal.<br />

The rising edge of input #4 signal.<br />

Entered command<br />

Any given command<br />

Any given command<br />

Any given command<br />

Any given command<br />

Any given command<br />

Power On<br />

When the network is connected: (Response interface: Ethernet)<br />

IN1<br />

IN2<br />

IN3<br />

IN4<br />

Start<br />

process<br />

Entered command<br />

at Start Up<br />

End<br />

process<br />

Start<br />

process<br />

Entered command<br />

at IN2<br />

End<br />

process<br />

If another command is running, the<br />

entered command at IN3 starts.<br />

But this command finished abnormally.<br />

(Error code:15xx)<br />

Start<br />

process<br />

Entered command<br />

at IN3<br />

End<br />

process<br />

WARNING: DO NOT enter the reset command at executing timing of start up.<br />