(3) SAVE communication setting (SAVE)<br />

This command allows the reader to write communication setting into the nonvolatile memories in the reader.<br />

If SET Communication command (SETC) is executed and then the reader is started up without executing<br />

this command (SAVE), new setting will be abandoned.<br />

Command<br />

SAVE<br />

Note: No arguments.<br />

Response<br />

SAVE[RC]<br />

[RC]: Response Code<br />

Example 1) When communication setting is saved (New setting is written into the nonvolatile memory):<br />

[Tx] SAVE<br />

[Rx] SAVE0000<br />