3.1.5.3 Communication Settings<br />
To set the conditions to communicate with tags, following items shall be specified in the SET Communication<br />
command (SETC) and GET Communication command (GETC). Specifying following option allows the reader<br />
to set or read the communication condition. To write the setting data into the nonvolatile memories in the<br />
reader, SAVE command (SAVE) shall be executed.<br />
Communication Settings [RF Control] (GETC/SETC)<br />
Code Content User Setting Value Factory Settings<br />
PW1 <strong>UHF</strong> power level at port #1 Given value<br />
31.5 (dBm)<br />
-Min: 10.0<br />
-Max: 31.5<br />
-Step: 0.5<br />
PW2 <strong>UHF</strong> power level at port #2 Same as PW1 31.5 (dBm)<br />
PW3 <strong>UHF</strong> power level at port #3 Same as PW1 31.5 (dBm)<br />
PW4 <strong>UHF</strong> power level at port #4 Same as PW1 31.5 (dBm)<br />
SS1 Gen2 Session value #1<br />
Choice<br />
0<br />
In case of Once Mode sequence<br />
SS2 Gen2 Session value #2<br />
In case of Repeat Mode<br />
sequence<br />
0 / 1 / 2 / 3<br />
Choice<br />
0 / 1 / 2 / 3<br />
CMD Communication mode Choice<br />
0: Normal mode<br />
EWL EPC word length Given value<br />
-Min : 0<br />
-Max : 32<br />
-Step : 1<br />
1: Dense reader mode (DRM)<br />
2<br />
0: Normal mode<br />
0 : Auto mode<br />
Communication Settings [Filtering] (GETC/SETC)<br />
Code Content User Setting Value Factory Settings<br />
FTE Filtering enable Choice<br />
0:None<br />
0: None<br />
1: Filter1 only<br />
2: Filter2 only<br />
1&2: Filter1 and Filter2<br />
1|2: Filter1 or Filter2<br />
FT1 Filtering condition #1 Format:<br />
(None)<br />
FileterType(S)MemBank(S)Point<br />
er(S)Length(S)Value<br />
FilterType: 0 (fixed)<br />
MemBank: 0 to 3<br />
Pointer: 0 to 255 (bit)<br />
Length: 1 to 255(bit)<br />
Value: XXXX…<br />
-Note: Set longer bits than the<br />
bits specified in the “Length” with<br />
2-digit hexadecimal number (“0”<br />
to “F”). Max: 64 characters. The<br />
most significant bit is a Pointer of<br />
the Value.<br />
FT2 Filtering condition #2 Same as FT1 (None)<br />
Communication Settings [Smoothing] (GETC/SETC)<br />
Code Content User Setting Value Factory Settings<br />
SBF Prevents repeat read -Min: 0 (Disable) 0:Disable<br />