3.1.5.3 Communication Settings<br />

To set the conditions to communicate with tags, following items shall be specified in the SET Communication<br />

command (SETC) and GET Communication command (GETC). Specifying following option allows the reader<br />

to set or read the communication condition. To write the setting data into the nonvolatile memories in the<br />

reader, SAVE command (SAVE) shall be executed.<br />

Communication Settings [RF Control] (GETC/SETC)<br />

Code Content User Setting Value Factory Settings<br />

PW1 <strong>UHF</strong> power level at port #1 Given value<br />

31.5 (dBm)<br />

-Min: 10.0<br />

-Max: 31.5<br />

-Step: 0.5<br />

PW2 <strong>UHF</strong> power level at port #2 Same as PW1 31.5 (dBm)<br />

PW3 <strong>UHF</strong> power level at port #3 Same as PW1 31.5 (dBm)<br />

PW4 <strong>UHF</strong> power level at port #4 Same as PW1 31.5 (dBm)<br />

SS1 Gen2 Session value #1<br />

Choice<br />

0<br />

In case of Once Mode sequence<br />

SS2 Gen2 Session value #2<br />

In case of Repeat Mode<br />

sequence<br />

0 / 1 / 2 / 3<br />

Choice<br />

0 / 1 / 2 / 3<br />

CMD Communication mode Choice<br />

0: Normal mode<br />

EWL EPC word length Given value<br />

-Min : 0<br />

-Max : 32<br />

-Step : 1<br />

1: Dense reader mode (DRM)<br />

2<br />

0: Normal mode<br />

0 : Auto mode<br />

Communication Settings [Filtering] (GETC/SETC)<br />

Code Content User Setting Value Factory Settings<br />

FTE Filtering enable Choice<br />

0:None<br />

0: None<br />

1: Filter1 only<br />

2: Filter2 only<br />

1&2: Filter1 and Filter2<br />

1|2: Filter1 or Filter2<br />

FT1 Filtering condition #1 Format:<br />

(None)<br />

FileterType(S)MemBank(S)Point<br />

er(S)Length(S)Value<br />

FilterType: 0 (fixed)<br />

MemBank: 0 to 3<br />

Pointer: 0 to 255 (bit)<br />

Length: 1 to 255(bit)<br />

Value: XXXX…<br />

-Note: Set longer bits than the<br />

bits specified in the “Length” with<br />

2-digit hexadecimal number (“0”<br />

to “F”). Max: 64 characters. The<br />

most significant bit is a Pointer of<br />

the Value.<br />

FT2 Filtering condition #2 Same as FT1 (None)<br />

Communication Settings [Smoothing] (GETC/SETC)<br />

Code Content User Setting Value Factory Settings<br />

SBF Prevents repeat read -Min: 0 (Disable) 0:Disable<br />