26.05.2014 Views

V750-series UHF RFID System User's Manual - PLCeasy

V750-series UHF RFID System User's Manual - PLCeasy

V750-series UHF RFID System User's Manual - PLCeasy

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Category<br />

Tag<br />

communicat<br />

ion error<br />

<strong>System</strong><br />

error<br />

Response Code<br />

Main<br />

70<br />

Sub<br />

Response<br />

Name<br />

1x Communication<br />

error<br />

2x Communication<br />

error<br />

71 00 Verification<br />

error<br />

7A<br />

7B<br />

7C<br />

00 Address<br />

specification<br />

error<br />

Description<br />

During the transaction after tag detection,<br />

communication error or process time out has occurred,<br />

and consequently the transaction can not be<br />

completed normally.<br />

Specified password does not match to the one of the<br />

target tag.<br />

During the transaction after tag detection,<br />

communication error or process time out has occurred,<br />

and consequently the transaction can not be<br />

completed normally.<br />

* In the case of ID write / Data write, a part of data in<br />

the tag may have been written.<br />

The reader has not written the data to the tag by<br />

reason of verification error.<br />

Specifying Bank/Address in the tag memory is<br />

incorrect and command can not be executed.<br />

00 Data write error During the data write into the detected tag, sufficient<br />

power is not supplied to the tag.<br />

1x Antenna<br />

detection error<br />

2x Antenna error<br />

At the R/W starts up, an appropriate antenna has not<br />

been connected to the specified antenna port.<br />

Error occurred with the antenna connected to the<br />

specified antenna port (even though the antenna is<br />

detected normally when start up).<br />

7E 00 Lock error When data write or read command is sent for the<br />

locked area. It depends on the tag’s chip<br />

specifications. (For Monza chip, when these<br />

commands are sent for Lock Bit of User Memory<br />

because this area does not exist.)<br />

7F xx Tag error The tag has been rejected the command process.<br />

9A xx <strong>System</strong> error An error that blocks command execution has been<br />

detected in the hardware (such as malfunction of inner<br />

circuit or temporary execution error caused by noise).<br />

‘x’ character in response code means one character in the list of 0 to 9 or A to F.<br />