V750-series UHF RFID System User's Manual - PLCeasy
V750-series UHF RFID System User's Manual - PLCeasy
V750-series UHF RFID System User's Manual - PLCeasy
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Category<br />
Tag<br />
communicat<br />
ion error<br />
<strong>System</strong><br />
error<br />
Response Code<br />
Main<br />
70<br />
Sub<br />
Response<br />
Name<br />
1x Communication<br />
error<br />
2x Communication<br />
error<br />
71 00 Verification<br />
error<br />
7A<br />
7B<br />
7C<br />
00 Address<br />
specification<br />
error<br />
Description<br />
During the transaction after tag detection,<br />
communication error or process time out has occurred,<br />
and consequently the transaction can not be<br />
completed normally.<br />
Specified password does not match to the one of the<br />
target tag.<br />
During the transaction after tag detection,<br />
communication error or process time out has occurred,<br />
and consequently the transaction can not be<br />
completed normally.<br />
* In the case of ID write / Data write, a part of data in<br />
the tag may have been written.<br />
The reader has not written the data to the tag by<br />
reason of verification error.<br />
Specifying Bank/Address in the tag memory is<br />
incorrect and command can not be executed.<br />
00 Data write error During the data write into the detected tag, sufficient<br />
power is not supplied to the tag.<br />
1x Antenna<br />
detection error<br />
2x Antenna error<br />
At the R/W starts up, an appropriate antenna has not<br />
been connected to the specified antenna port.<br />
Error occurred with the antenna connected to the<br />
specified antenna port (even though the antenna is<br />
detected normally when start up).<br />
7E 00 Lock error When data write or read command is sent for the<br />
locked area. It depends on the tag’s chip<br />
specifications. (For Monza chip, when these<br />
commands are sent for Lock Bit of User Memory<br />
because this area does not exist.)<br />
7F xx Tag error The tag has been rejected the command process.<br />
9A xx <strong>System</strong> error An error that blocks command execution has been<br />
detected in the hardware (such as malfunction of inner<br />
circuit or temporary execution error caused by noise).<br />
‘x’ character in response code means one character in the list of 0 to 9 or A to F.<br />
61 of 135