3.1.2 Command Code List<br />

Following is a list of the supported command codes. Each command is represented with four characters.<br />

Command Code List<br />

Command<br />

Command Name<br />

Code<br />

(1) Communication Command (to communicate with tags)<br />

Description<br />

Executable in<br />

communication<br />

RDID Read ID Reads ID data from the tag memory. No<br />

WTID Write ID Writes ID data into the tag memory. No<br />

RDDT Read Data Reads data from the tag memory (including passwords). No<br />

WTDT Write Data Writes data to the tag memory (including passwords). No<br />

LOCK Lock Sets Lock function in the tag. No<br />

KILL Kill Disables the tag permanently. No<br />

(2) Setting Command (to set a condition).<br />

SETR Set Reader Sets the function settings in the reader. No<br />

GETR Get Reader Reads the function settings from the reader. No<br />

SETC<br />

Set Communication<br />

Sets the communication settings in the reader (temporary<br />

setting).<br />

GETC Get Communication Reads the communication settings from the reader. No<br />

SETO Set Reader Operation Sets the operation settings in the reader. No<br />

GETO Get Reader Operation Reads the operation settings from reader. No<br />

SAVE<br />

Save communication<br />

settings<br />

(3) Control command (to control the action)<br />

Save the communication condition into the nonvolatile<br />

memories in the reader (permanent setting).<br />

INIT Initialize Initializes all settings in the reader. No<br />

STOP Stop Stops the communication with the tags. Yes<br />

EXIO<br />

External Input Output<br />

control<br />

Reads input/output port status.<br />

Sets condition of output port.<br />

REST Reset Restarts the reader. Yes<br />

GBYE Good Bye Disconnects the Ethernet connection. No<br />

RRES Request Resend Requests to resend the last response data. Yes<br />

TEST Test <strong>System</strong> Tests the communication between host and the reader. Yes<br />

Reads the operation status from reader.<br />

NOIS Noise monitoring Monitors noise level of the specified antenna. No<br />

(4) Undefined command (in the response frame only)<br />

ICMD<br />

Illegal Command<br />

Command code to be used in the response frame if the R/W<br />

receives undefined command.<br />

No<br />

No<br />

Yes<br />

-<br />