3.1.2 Command Code List<br />
Following is a list of the supported command codes. Each command is represented with four characters.<br />
Command Code List<br />
Command<br />
Command Name<br />
Code<br />
(1) Communication Command (to communicate with tags)<br />
Description<br />
Executable in<br />
communication<br />
RDID Read ID Reads ID data from the tag memory. No<br />
WTID Write ID Writes ID data into the tag memory. No<br />
RDDT Read Data Reads data from the tag memory (including passwords). No<br />
WTDT Write Data Writes data to the tag memory (including passwords). No<br />
LOCK Lock Sets Lock function in the tag. No<br />
KILL Kill Disables the tag permanently. No<br />
(2) Setting Command (to set a condition).<br />
SETR Set Reader Sets the function settings in the reader. No<br />
GETR Get Reader Reads the function settings from the reader. No<br />
SETC<br />
Set Communication<br />
Sets the communication settings in the reader (temporary<br />
setting).<br />
GETC Get Communication Reads the communication settings from the reader. No<br />
SETO Set Reader Operation Sets the operation settings in the reader. No<br />
GETO Get Reader Operation Reads the operation settings from reader. No<br />
SAVE<br />
Save communication<br />
settings<br />
(3) Control command (to control the action)<br />
Save the communication condition into the nonvolatile<br />
memories in the reader (permanent setting).<br />
INIT Initialize Initializes all settings in the reader. No<br />
STOP Stop Stops the communication with the tags. Yes<br />
EXIO<br />
External Input Output<br />
control<br />
Reads input/output port status.<br />
Sets condition of output port.<br />
REST Reset Restarts the reader. Yes<br />
GBYE Good Bye Disconnects the Ethernet connection. No<br />
RRES Request Resend Requests to resend the last response data. Yes<br />
TEST Test <strong>System</strong> Tests the communication between host and the reader. Yes<br />
Reads the operation status from reader.<br />
NOIS Noise monitoring Monitors noise level of the specified antenna. No<br />
(4) Undefined command (in the response frame only)<br />
ICMD<br />
Illegal Command<br />
Command code to be used in the response frame if the R/W<br />
receives undefined command.<br />
No<br />
No<br />
Yes<br />
-<br />