2. Functions and Control<br />
Reference Guide<br />
This chapter lays the groundwork for the communication protocol between client software running on a remote<br />
computer and the <strong>V750</strong> reader.<br />
2.1 Reader Operating Mode<br />
Reader operating mode contains three modes, Operation Mode, Safe Mode and Update Mode.<br />
Mode Function Note<br />
Operation Mode:<br />
Safe Mode:<br />
Update Mode:<br />
Under this mode, the reader<br />
communicates tags normally.<br />
Under this mode, the reader<br />
recovers or is maintained<br />
after error.<br />
Under this mode, the reader<br />
updates firmware.<br />
If you push the Mode Switch for 1 second or more<br />
and release the switch while the system is<br />
running, or if the reader detects an error (ex.<br />
<strong>System</strong> error or a failure of firmware update), and<br />
it can not start up normally due to this error, the<br />
reader will start up under Safe Mode. Under this<br />
mode, you can check the status via Web browser,<br />
initialize the setting and install the firmware.<br />