3.1.5.2 Reader Status, Reader Settings Function<br />

To set the Reader Status and Reader Settings, following items shall be specified in the SET Reader command<br />

(SETR) and GET Reader command (GETR). The Reader Status is available only for reading data.<br />

Reader Status [Static / Read only] (GETR)<br />

Code Content Fixed Value (=Factory Settings)<br />

MFT Manufacturer “OMRON Corporation”<br />

TYP Type of the reader “<strong>V750</strong>-BA50D04-SG” or “<strong>V750</strong>-BA50D04-SG-MY”<br />

FWV Firmware version xxx-xxx-xxx-x<br />

SER Serial number “xxxxxxxx”<br />

MAC MAC address 00:00:0A:89:xx:xx<br />

Reader Status [Dynamic / Read only] (GETR)<br />

Code Content Variable Value<br />

ATS Antenna status<br />

(Connected Antenna)<br />

TTK Transition time from kick hhhh:mm:ss<br />

-Min: 00:00:00<br />

-Max: 9999:59:59<br />

xxxxx (x:1 to 4)<br />

-ex1. All antennas are connected: 1234<br />

-ex2. Antenna #1 and antenna #4 are connected: 14<br />

Reader Settings [Reader Information] (GETR/SETR)<br />

Code Content User Setting Value Factory Settings<br />

RNM Reader name Given string<br />

(None)<br />

-Min: 1 characters , ASCII<br />

-Max: 63 characters, ASCII<br />

-Note: This setting value has double<br />

quotation marks.<br />

RRL Reader’s role Given string<br />

-Min: 1 characters , ASCII<br />

-Max: 63 characters , ASCII<br />

-Note: This setting value has double<br />

quotation marks.<br />