3.1.5.4 Operation Settings<br />
Specifying following option in the operation setting command (SETO) or operation read command (GETO)<br />
enables to set or read the reader’s operation settings.<br />
Operation Settings [Command Entry] (GETO/SETO)<br />
Code Content User Setting Value Factory Settings<br />
RIF Response Interface Choice<br />
1:Ethernet<br />
0:None<br />
1:Ethernet<br />
2:RS-232C<br />
IEC Command to be<br />
execute at startup.<br />
Given string<br />
Format: Function(S)”Command”<br />
(None)<br />
Function<br />
0: unregistered<br />
1: execute command<br />
IN1<br />
Input port #1 function<br />
setting<br />
“Command”<br />
Command to be execute<br />
ex. “RDID –seq SOC –tmo 500”<br />
-Max: 255 characters, ASCII<br />
-Note: This setting value has double<br />
quotation marks.<br />
Format: Function(S)Timing(S)”Command”<br />
Function<br />
0:None<br />
1:Command execution<br />
(None)<br />
Timing<br />
0:Startup (Fixed)<br />
IN2<br />
IN3<br />
IN4<br />
Input port #2 function<br />
setting<br />
Input port #3 function<br />
setting<br />
Input port #4 function<br />
setting<br />
“Command”<br />
Command to be execute<br />
Ex. “RDID –seq SOC –tmo 500”<br />
-Max: 255 characters, ASCII<br />
-Note: This setting value has double<br />
quotation marks.<br />
-Note: Only when the Function is specified<br />
with “1”, set the Timing and the “Command”.<br />
When the Function is specified with “0”,<br />
executed “Command” data is saved and<br />
response data is returned.<br />
Same as IN1<br />
Same as IN1<br />
Same as IN1<br />
(None)<br />
(None)<br />
(None)<br />
82 of 135