Photo sensor<br />
Item Meaning Connection<br />
Sensor<br />
Detects the forklift is coming to the portal gate.<br />
* When the sensor detects the forklift, the signal<br />
line is turned Off to On<br />
The signal line is connected input<br />
port #1 of the reader.<br />
Stack lights<br />
Item Meaning Connection<br />
Light1(Blue)<br />
Means that all tags were read.<br />
* When the signal line is turn Off to On, the light is<br />
turned on.<br />
The signal line is connected output<br />
port #1 of the reader.<br />
Light2(Yellow)<br />
Light3(Red)<br />
Means in communication.<br />
* When the signal line is turn Off to On, the light is<br />
turned on.<br />
Means that read tags ware insufficient.<br />
* When the signal line is turn Off to On, the light is<br />
turned on.<br />
The signal line is connected output<br />
port #2 of the reader.<br />
The signal line is connected output<br />
port #3 of the reader.<br />
Communication sequence (All tags are read normally.)<br />
Host<br />
Response<br />
Sensor<br />
On<br />
Stack Lights<br />
Blue<br />
Lighting<br />
1000ms<br />
Yellow<br />
Lighting<br />
2000ms<br />
Red<br />
Input port #1:On<br />
Output port #2:On<br />
Output port #1:On<br />
Output port #2:Off<br />
Output port #1:Off<br />
Reader<br />
In communication<br />
2000ms<br />
Judgment<br />
Tag<br />
Tag1 Tag2 Tag3 Tag4 Tag5 Tag6<br />
Tag7<br />
Tag8<br />
Tag9<br />
All tags are were read.<br />