Glare-reduced lighting of playing fields to DIN EN 12193<br />

for football, handball, hockey etc.<br />

Lighting for football training fields with asymmetrical plane floodlights 7574...<br />

Field data: Size: 105m x 65m<br />

Poles: 6<br />

Height of poles: 16m<br />

Distance to the ground: ca. 4m<br />

Selected lighting:<br />

6 x type 7574/2000HI<br />

lamp: OSRAM HQI-T 2000N<br />

+ 6 x ballast housing 1032/2000HI 10,3 comp<br />

or<br />

+ 6 assembly units for location inside poles<br />

type 10160/2000HI 10,3 compensated or<br />

type 10161/2000HI 10,3 compensated<br />

The above solution meets all the requirements<br />

to DIN EN 12193 in respect to light<br />

intensity and evenness. At the same time<br />

special attention is given to the evenness<br />

of the light intensity, maximum glare limitation<br />

and minimum light scatter.<br />

No ignitors are necessary for the selected<br />

lighting types, the distance between the<br />

electrical control gear and light fitting is<br />

not important for the safe ignition of the<br />

lamps. The fuse protection must be made<br />

on site when using the mounting accessories<br />

type 10161<br />