Polyester Damp Room Emergency Light Fittings<br />
without Diffusers<br />
Series 175...<br />
Application:<br />
In workshops and to illuminate and indicate<br />
escape routes according to DIN V<br />
VDE V0108-100 and EN 1838.<br />
Mechanical design:<br />
Enclosure: glass fibre reinforced polyester<br />
with press-in studs.<br />
Seal: weather, ageing and chemical resistant<br />
profile seal.<br />
Electrical components: mounted inside<br />
on the removable back plate of the light<br />
fitting. Starter easily accessible from outside.<br />
Damp room lamp holders with double<br />
slotted contacts and neoprene gasket.<br />
Electrical connection: 3-pole connection<br />
terminal.<br />
Through wiring: up to 5 x 2,5mm² possible.<br />
Cable entries: variable, at the ends and<br />
top of the housing, also available for looping<br />
in/out at one end, 2 x blanking<br />
plugs M20.<br />
Mounting system: pre-pressed holes for<br />
direct ceiling mounting. Rubber gaskets<br />
for sealing are supplied with the fitting.<br />
Wiring diagram 175 1... maintained operation<br />
light switch<br />
Battery conductor<br />
Electrical design:<br />
Built-in NiCd battery, a constant trickle<br />
charge to the battery ensures readiness<br />
of operation at all times.<br />
Visual function monitoring the battery<br />
charging process with LED.<br />
Electronic deep discharge protection<br />
Recharging time: 24 hours acc. to EN<br />
60598-2-22.<br />
Modes of operation:<br />
Maintained mode = change-over to battery<br />
operation on mains failure. With the<br />
2-lamp version, only one lamp is operated<br />
as emergency lighting (Series 175 2).<br />
Mains voltage: 230V, 50Hz<br />
Ambient temperature:<br />
-5°C to +30°C for maintained mode<br />
-5°C to +40°C for stand-by mode<br />
Wiring diagram 175 2... maintained operation<br />
light switch<br />
emergency light fitting<br />
Battery conductor<br />
emergency light fitting<br />
Starting: Connect battery conductor<br />
Out of operation:<br />
Disconnect battery conductor<br />
Stand-by operation: Do not connect L1'<br />
175 ...<br />
with self-contained battery<br />
T 26<br />
Type Article no. Lamps/ Flux factor Weight<br />
W about % 2) about kg 4)<br />
1 h operation time, with conventional ballast<br />
175 1<strong>58</strong>/../. 175 136/18/1 17510 0005 1 x T 26/36 W 18 2,7<br />
175 1<strong>58</strong>/15/1 17510 0006 1 x T 26/<strong>58</strong> W 15 3,2<br />
175 236/18/1 3) 17510 0007 2 x T 26/36 W 18 4,6<br />
175 2<strong>58</strong>/15/1 3) 17510 0008 2 x T 26/<strong>58</strong> W 15 5,7<br />
1 h operation time, with electronic ballast (EVG)<br />
175 136/18/1 EVG 17510 0009 1 x T 26/36 W 18 2,3<br />
175 1<strong>58</strong>/15/1 EVG 17510 0010 1 x T 26/<strong>58</strong> W 15 2,5<br />
175 236/18/1 EVG 17510 0011 2 x T 26/36 W 18 3,2<br />
175 2<strong>58</strong>/15/1 EVG 17510 0012 2 x T 26/<strong>58</strong> W 15 2,6<br />
1) Only uncompensated<br />
2) Ratio effective lamp flux to rated current<br />
IP65<br />
3) Version for 3 h operating duration not possible<br />
4) Weights without packing material<br />
Series 175 1.. Series 175 2..<br />
Bitte Subject beachten to technical Sie die changes, Hinweise im misprints Technischen and Anhang! errors.<br />
Technische Änderungen, Druckfehler und Irrtümer vorbehalten.<br />
276