Polyester Damp Room Emergency Light Fittings<br />

without Diffusers<br />

Series 175...<br />

Application:<br />

In workshops and to illuminate and indicate<br />

escape routes according to DIN V<br />

VDE V0108-100 and EN 1838.<br />

Mechanical design:<br />

Enclosure: glass fibre reinforced polyester<br />

with press-in studs.<br />

Seal: weather, ageing and chemical resistant<br />

profile seal.<br />

Electrical components: mounted inside<br />

on the removable back plate of the light<br />

fitting. Starter easily accessible from outside.<br />

Damp room lamp holders with double<br />

slotted contacts and neoprene gasket.<br />

Electrical connection: 3-pole connection<br />

terminal.<br />

Through wiring: up to 5 x 2,5mm² possible.<br />

Cable entries: variable, at the ends and<br />

top of the housing, also available for looping<br />

in/out at one end, 2 x blanking<br />

plugs M20.<br />

Mounting system: pre-pressed holes for<br />

direct ceiling mounting. Rubber gaskets<br />

for sealing are supplied with the fitting.<br />

Wiring diagram 175 1... maintained operation<br />

light switch<br />

Battery conductor<br />

Electrical design:<br />

Built-in NiCd battery, a constant trickle<br />

charge to the battery ensures readiness<br />

of operation at all times.<br />

Visual function monitoring the battery<br />

charging process with LED.<br />

Electronic deep discharge protection<br />

Recharging time: 24 hours acc. to EN<br />

60598-2-22.<br />

Modes of operation:<br />

Maintained mode = change-over to battery<br />

operation on mains failure. With the<br />

2-lamp version, only one lamp is operated<br />

as emergency lighting (Series 175 2).<br />

Mains voltage: 230V, 50Hz<br />

Ambient temperature:<br />

-5°C to +30°C for maintained mode<br />

-5°C to +40°C for stand-by mode<br />

Wiring diagram 175 2... maintained operation<br />

light switch<br />

emergency light fitting<br />

Battery conductor<br />

emergency light fitting<br />

Starting: Connect battery conductor<br />

Out of operation:<br />

Disconnect battery conductor<br />

Stand-by operation: Do not connect L1'<br />

175 ...<br />

with self-contained battery<br />

T 26<br />

Type Article no. Lamps/ Flux factor Weight<br />

W about % 2) about kg 4)<br />

1 h operation time, with conventional ballast<br />

175 1<strong>58</strong>/../. 175 136/18/1 17510 0005 1 x T 26/36 W 18 2,7<br />

175 1<strong>58</strong>/15/1 17510 0006 1 x T 26/<strong>58</strong> W 15 3,2<br />

175 236/18/1 3) 17510 0007 2 x T 26/36 W 18 4,6<br />

175 2<strong>58</strong>/15/1 3) 17510 0008 2 x T 26/<strong>58</strong> W 15 5,7<br />

1 h operation time, with electronic ballast (EVG)<br />

175 136/18/1 EVG 17510 0009 1 x T 26/36 W 18 2,3<br />

175 1<strong>58</strong>/15/1 EVG 17510 0010 1 x T 26/<strong>58</strong> W 15 2,5<br />

175 236/18/1 EVG 17510 0011 2 x T 26/36 W 18 3,2<br />

175 2<strong>58</strong>/15/1 EVG 17510 0012 2 x T 26/<strong>58</strong> W 15 2,6<br />

1) Only uncompensated<br />

2) Ratio effective lamp flux to rated current<br />

IP65<br />

3) Version for 3 h operating duration not possible<br />

4) Weights without packing material<br />

Series 175 1.. Series 175 2..<br />

Bitte Subject beachten to technical Sie die changes, Hinweise im misprints Technischen and Anhang! errors.<br />

Technische Änderungen, Druckfehler und Irrtümer vorbehalten.<br />

276

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!