164... KL LED/. MA<br />

with self-contained battery and automatic self-monitoring<br />

Application:<br />

In humid, wet and dusty locations in<br />

commercial and industrial premises, cold<br />

rooms, walkable cool cabins etc. for<br />

emergency lighting as well as for illuminating<br />

and indicating any escape routes.<br />

Mechanical design:<br />

As standard version but:<br />

Diffuser: Opalescent white (W) PMMA.<br />

IP65<br />

(Pictograms – if required – to be ordered<br />

separately, see accessories).<br />

Reflector: Painted aluminium.<br />

Connection terminal: 4 poles<br />

Connection voltage: 230V, 50Hz<br />

LED: Highpower LED 1W, white 6,500K<br />

Options:<br />

Please see “Further series/equipment”.<br />

Diagram “maintained/stand-by wiring”<br />

Electrical design:<br />

NiCd battery, a constant trickle charge to<br />

the battery ensures readiness of operation<br />

at all times.<br />

Electronic deep discharge protection.<br />

Recharging time:<br />

24 h, acc. to EN 60598-2-22.<br />

Automatic monitoring the emergency<br />

light fitting acc. to EN 62034. 2 coloured<br />

LED on the light fitting indicate the test<br />

results (.../MA).<br />

Modes of operation:<br />

Maintained operation: Switch over to<br />

battery operation in case of mains failure.<br />

Stand-by operation: Emergency lamp<br />

switches on in case of mains failure.<br />

Advantages of LED-version<br />

• up to 71% energy saving in comparison with an 8W fluorescent lamp<br />

Installation: Connect battery conductor<br />

Decommission: Disconnect battery conductor<br />

Stand-by operation: Do not connect L1'<br />

• safety in an emergency , immediate full light output (100% luminous flux) even at low temperatures<br />

• stable luminous flux in the emergency operation independent from the ambient temperature<br />

• outstanding even illumination of the pictogram fulfills EN 1838 and DIN 4844<br />

• reduced battery capacity<br />

• little thermal stress<br />

• low weight<br />

• almost maintenance-free operation due to long operation life of the LED (≥ 50,000h)<br />

• no costs for lamp replacement<br />

LED<br />

Type Article . Qty. LED Operating Flux factor Power<br />

no. W time h about% 1) consumption<br />

maintained operation<br />

164 201 W KL LED/1/MA 16408 0001 2 x 1 W 1 100 4W<br />

164 201 W KL LED/3/MA 16408 0002 2 x 1 W 3 100 4W<br />

1) Ratio effective lamp flux to rated current<br />

Energy cost savings<br />

using LED Series 164... KL<br />

Energy costs in %<br />

71%<br />

Note:<br />

The data given for the LED is relevant at the<br />

time of print. Changes based on technical<br />

advancements see web-site under<br />

www.schuch.de.<br />

The given values for energy savings are approximate.<br />

These are dependent on the individual<br />

lamps used and the built-in<br />

apparatus.<br />

Guarantee claims based on this data are excluded.<br />

164... KL LED ZB<br />

NEW<br />

for central battery systems<br />

LED<br />

Application:<br />

For connection to group or central battery<br />

systems or to an emergency mains for illuminating<br />

and identifying escape routes..<br />

Type Article no. . Qty. LED Power/ Weight<br />

W consumption about kg 1)<br />

white opaque PMMA glass<br />

164 201 W KL LED ZB 16408 0003 2 x 1,0W 4W 100 0,9<br />

164 601 W KL LED ZB 16408 0004 6 x 1,0W 8W 120 0,9<br />

164 603 W KL LED ZB 16408 0005 6 x 2,5W 16W 120 0,9<br />

1) Weights without packing material<br />

IP65<br />

Electrical design:<br />

ECG: For operation on 230V AC and 220V<br />

DC with incorporated fuse for selective cutoff<br />

in case of failure according to DIN EN<br />

60598-2-22, VDE 0711-2-22, section 22.6.3.<br />

Emergency Notleuchten Light Fittings<br />

Bitte Subject beachten to technical Sie die changes, Hinweise imisprints Technischen andAnhang!<br />

errors.<br />

Technische Änderungen, Druckfehler und Irrtümer vorbehalten.<br />