7-22 Replacing the Flat Target Sensor PC Board<br />

Note: PC Boards are susceptible to damage from static electricity. Anti static<br />

precautions should be taken when removing, handling and refitting the PC<br />

Board.<br />

1. Remove the Flat Target Assembly. (See Section 7-18 page 77).<br />

2. Disconnect connectors (J301) and (J302).<br />

Locking Supports<br />

Front<br />

Connector<br />

(J301)<br />

Connector<br />

(J302)<br />

Flat Target<br />

Sensor PC Board<br />

3. Using needle nosed pliers, squeeze the locking tabs of the locking supports, one<br />

at a time, to release the PC Board. Remove the Sensor PC Board.<br />

PC Board<br />

Tab<br />

Locking Support<br />

Stopper<br />

Needle Nosed<br />

Pliers<br />

4. Replace the board by gently pushing the board on to the locking supports.<br />

Note: When replacing the Sensor Pc Board, ensure that connector (J301) is located at<br />

the front.<br />

Page 83