Computing a Link Volume Factor (Cont’d)<br />

►Use the following formula to calculate the link<br />

volume factor per link using the Link Attribute<br />

Calculator in Cube:<br />

Link Volume Factor =<br />

Selected Link Volume<br />

Total External Project Trips<br />

►Once the link volume factor has been calculated, it<br />

is then possible to factor the ITE trip generation<br />

volume for the site.<br />

<strong>FSUTMS</strong>--CUBE MODELING TRAINING SERIES<br />

43<br />

Computing a Link Volume Factor (Cont’d)<br />

<strong>FSUTMS</strong> Output<br />

(Development Trips)<br />

ITE Generated<br />

Development Trip Loadings<br />

1,000<br />

External<br />

ITE = 1,500<br />

300 700<br />

30% 70%<br />

Distribution Factors<br />

(Manually Calculated)<br />

1,500<br />

X 30%<br />

450<br />

1,500<br />

X 70%<br />

1,050<br />