order. Safety needs <strong>to</strong> be documented in order <strong>to</strong> pass information<br />

<strong>to</strong> different engineering disciplines.<br />

For the <strong>oil</strong> <strong>and</strong> <strong>gas</strong> industry, safety st<strong>and</strong>ards comprise a set of corporate,<br />

national <strong>and</strong> international laws, guidelines <strong>and</strong> st<strong>and</strong>ards. Some of the<br />

primary international st<strong>and</strong>ards are:<br />

• IEC 61508 Functional safety of electrical/electronic/programmable<br />

electronic safety-related systems<br />

• IEC 61511 Functional safety - Safety instrumented systems for the<br />

process industry sec<strong>to</strong>r<br />

A safety integrity level is not directly applicable <strong>to</strong> individual subsystems or<br />

components. It applies <strong>to</strong> a safety function carried out by the safety<br />

instrumented system (end-<strong>to</strong>-end: sensor, controller <strong>and</strong> final element).<br />

IEC 61508 covers all components of the E/E/PE safety-related system,<br />

including field equipment <strong>and</strong> specific project application logic. All these<br />

subsystems <strong>and</strong> components, when combined <strong>to</strong> implement the safety<br />

function (or functions), are required <strong>to</strong> meet the safety integrity level target of<br />

the relevant functions. <strong>An</strong>y design using supplied subsystems <strong>and</strong><br />

components that are all quoted as suitable for the required safety integrity<br />

level target of the relevant functions will not necessarily comply with the<br />

requirements for that safety integrity level target.<br />

Suppliers of products intended for use in E/E/PE safety-related systems<br />

should provide sufficient information <strong>to</strong> facilitate a demonstration that the<br />

E/E/PE safety-related system complies with IEC 61508. This often requires<br />

that the functional safety for the system be independently certified.<br />

There is never one single action that leads <strong>to</strong> a large accident. It is often a<br />

chain of activities. There are many layers <strong>to</strong> protect against an accident, <strong>and</strong><br />

these are grouped two different categories:<br />

• Protection layers – <strong>to</strong> prevent an incident from happening. Example:<br />

rupture disk, relief valve, dike.<br />

• Mitigation layers – <strong>to</strong> minimize the consequence of an incident.<br />

Example: Opera<strong>to</strong>r intervention or safety instrumented system (SIS)<br />

<strong>An</strong> SIS is a collection of sensors, controllers <strong>and</strong> actua<strong>to</strong>rs that execute one<br />

or more SIFs/safety loops that are implemented for a common purpose.<br />

Each SIF has its own safety integrity level (SIL) <strong>and</strong> all sensors, controllers<br />

<strong>and</strong> final elements in one SIF must comply with the same SIL, i.e., the end-<br />

104