<strong>Annual</strong> Research <strong>Report</strong> <strong>2011</strong>-<strong>2012</strong><br />

Project Title:<br />

Performance test and tuning of 5 to 8 gas turbine units of<br />

Kerman combined cycle power plant<br />

Department: Measurement & Control Department<br />

Employer: Kerman power production company<br />

Project Staff: S. Shahmansouri, N. Irani, H.R. Khalesi,<br />

Project Manager: Edward Gharibian<br />

Project Code: CECTBK01<br />

Project Summary:<br />

Performance of gas turbine units are affected by ambient conditions namely ambient<br />

temperature, pressure and humidity. Hence gas turbine control systems are designed so<br />

that they maintain the optimal performance of gas turbine in variety of conditions.<br />

Optimal performance means setting turbine to work safely at its maximum permissible<br />

power. Due to sensitivity of gas turbine to ambient condition after major overhauls,<br />

tuning of control system settings is necessary for optimal operation of gas turbine.<br />

These settings are done by performance testing of unit and calculation of combustion<br />

products entering first stage of turbine. Precise calculation is vital because if the<br />

temperature is set to lower value the unit cannot produce at its maximum power and will<br />

result in loss of production and if temperature is set to higher value the life of first stage<br />

blades will reduce and event may damage these blades. In this project the settings of<br />

V94.2 gas turbine of Kerman power plant were tested and tuned for optimal<br />

performance of unit.<br />

Project Results:<br />

• Performance test and tuning of Kerman power plant V94.2 gas turbines<br />

Project Documentation:<br />

• <strong>Report</strong> of performance test of unit no 2 / CECTDK01/05<br />

• <strong>Report</strong> of performance test of unit no 3 / CECTDK01/04<br />

• <strong>Report</strong> of performance test of unit no 4 / CECTDK01/02<br />

• <strong>Report</strong> of performance test of unit no 5 / CECTDK01/03<br />

49