10.07.2015 Views

Shaping the Energy Efficiency in New Buildings - Building Energy ...

Shaping the Energy Efficiency in New Buildings - Building Energy ...

Shaping the Energy Efficiency in New Buildings - Building Energy ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>the</strong>rmal requirements for roofs, floors and w<strong>in</strong>dows because it has particularly str<strong>in</strong>gentrequirements for electrically heated build<strong>in</strong>gs. Canadian U-factors for build<strong>in</strong>gs withnatural gas heat<strong>in</strong>g are much lower. The United States has <strong>the</strong> most str<strong>in</strong>gentrequirements for walls. Exclud<strong>in</strong>g Canada’s electrically heated build<strong>in</strong>gs, India has <strong>the</strong>most str<strong>in</strong>gent wall requirements and Ch<strong>in</strong>a has <strong>the</strong> most str<strong>in</strong>gent w<strong>in</strong>dow U-values.Ch<strong>in</strong>a’s <strong>the</strong>rmal requirements for opaque build<strong>in</strong>g envelope components for commercialbuild<strong>in</strong>gs are average for this climate zone. Figure 4 highlights <strong>the</strong> w<strong>in</strong>dow U-factors,while Table 13 provides details on <strong>the</strong> range of requirements <strong>in</strong> <strong>the</strong> very cold climatezone.Figure 4 Comparison of Wall U-factor Requirements <strong>in</strong> <strong>the</strong> Very Cold Zone0.60.50.4U-factor0.3Low maximumHigh maximumMidpo<strong>in</strong>t0.20.10Harb<strong>in</strong>, CHN(Residential)Calgary, CANHarb<strong>in</strong>, CHN(Commercial)Duluth, USALeh, INDTable 14 Thermal Characteristics of Roofs, Walls, Floors and W<strong>in</strong>dows <strong>in</strong> <strong>the</strong> Very Cold ZoneCitiesCalgaryCANHarb<strong>in</strong>CHNMaximum U-factors W/(m²·K)W<strong>in</strong>dow IndicatorsRoof Wall Floor W<strong>in</strong>dow0.22 (Type I),Maximum U-factor:0.29 (Type II0.33 (Non natural2.80 to 1.40 (Non naturalby electricitygas), 0.55gas) and 3.40 to 1.90and o<strong>the</strong>r), and(Natural gas)(Natural gas) by WWR.0.47 (Type IIO<strong>the</strong>rs)0.23 (Type II),0.29 (Type IIInon naturalgas), and 0.47(Type IIInatural gas)0.30-0.35 0.40-0.45 0.40-0.45Maximum U-factor: 3.0 to1.7 by WWR0.30-0.50 0.40-0.52 0.30 to 0.52 Maximum U-factor: 2.544

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!