Simulator ReferenceHWINON / HWINOFF / HWINFLASHSets the state of a hardware input. Under some conditions, this may be better thansetting the input variable using TRUE or NTRUE, because the variable value does notrevert to the hardware input value when inputs are evaluated. HWINFLASH allows theinput to be simulated as flashing, which is more difficult to do with TRUE or NTRUEcommands or simulation logic.Formats:whereExamples:LCLOSEHWINON var-name (turn input ON)HWINOFF var-name (turn input OFF)HWINFLASH var-name, flash-rate (turn input FLASHING)var-name is the name of the variable associated with the inputflash-rate is the flash rate in milliseconds. NOTE: very fast rates may notsimulate accurately; rates in the hundreds of milliseconds are more stable.See LOPEN.HWINON 1W-DIHWINFLASH FLASHIN-NVI 500P2512A, Rev. Oct/09 12–43 Alstom <strong>Signaling</strong> <strong>Inc</strong>.