13.07.2015 Views

Strategic Flood Risk Assessment - South Worcestershire ...

Strategic Flood Risk Assessment - South Worcestershire ...

Strategic Flood Risk Assessment - South Worcestershire ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Greenfield Runoff Rate (l/s/ha)Estimated Attenuation Storage Volume (m 3 ) 80 – 120SUDS and the development site:SUDS TypeSource ControlInfiltrationDetentionFiltrationConveyancePotentialSuitabilityComments1 in 2 year 111 in 100 year (plus climate change) 42.6Most source control techniques are likely to be suitable. Permeablepaving is unlikely to be suitable due to high risk of groundwaterfloodingMapping suggests underlying soil is likely to be permeable. Howeverthe high risk of groundwater flooding would make infiltrationunsuitableDetention techniques may be suitable if a non-permeable liner isprovided to prevent the ingress of groundwaterFiltration techniques may be suitable if a non-permeable liner isprovided to prevent the ingress of groundwaterAll conveyance techniques are likely to be suitable<strong>Flood</strong> Defences:None.The site is not located within a groundwater source protection zone.Residential developments should provide at least two independent SUDS features inseries to provide a suitable level of water quality treatment.Effects of Climate Change:Increased rainfall intensity. Increased water levels in an unnamed tributary of Whiteacres Brook.<strong>Flood</strong> <strong>Risk</strong> Implications for Development:All development should be located within <strong>Flood</strong> Zone 1, unless appropriate inaccordance with NPPF Technical Guidance.A detailed site-specific flood risk assessment, including hazard mapping, will berequired for any development in <strong>Flood</strong> Zone 2, or for sites greater than 1ha in <strong>Flood</strong>Zone 1.A culvert is located through the site.Development of the site is proposed to focus on residential uses.Resilience measures will be required if buildings are situated in the flood risk area.Green infrastructure should be considered within the mitigation measures for surfacewater runoff from potential development.<strong>Assessment</strong> for runoff should include allowance for climate change effects.New or re-development should adopt exemplar source control SUDS techniques toreduce the risk of frequent low impact flooding due to post-development runoff.Onsite attenuation schemes would need to be tested against the hydrograph of thereceiving watercourse to ensure flows are not exacerbated downstream within thecatchment.The site falls within an area indicated to potentially be susceptible to groundwateremergence. Further assessment of groundwater risk would be required and anassessment of suitable surface water mitigation techniques should be made at thedetailed FRA level.The Mayfield Road and the Elgar Avenue road, the main access roads to the site,are at risk from fluvial flooding and surface water. Suitable alternative accessarrangements away from the floodplain will need to be investigated further.Demonstration that development at this location can be made safe.2012s5947 S <strong>Worcestershire</strong> Level 2 SFRA Update FINAL Report v1.0.doc 124

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!