<strong>Maintenance</strong> (Continued)4. Check the frame-face runout by rotating the shaft so that the indicator measures the fit for 360º.If the total indicator reading is greater than 0.001 in. (0.025 mm), then disassemble <strong>and</strong> determine thecause.SCALE 0.1505. Place the manila gasket (360D) on the frame (228), <strong>and</strong> hold the gasket in place by inserting the dowelpins (469B) in their holes.The gasket is designed to fit only one way.6. Install the frame adapter.a) Place the frame adapter (108) onto the frame assembly.b) Align the bolt holes <strong>and</strong> dowel locations on the frame adapter with the bolt holes <strong>and</strong> dowellocations on the frame.98 Model 3796 i-FRAME <strong>Installation</strong>, <strong>Operation</strong>, <strong>and</strong> <strong>Maintenance</strong> <strong>Manual</strong>