<strong>Maintenance</strong> (Continued)333AINPRO labyrinth oil seal descriptionDescriptionThe INPRO VBXX-D Labyrinth Oil Seal consists of the rotor (1), the stator (2), <strong>and</strong> the VBX Ring (3).The rotor (1) fits over the shaft <strong>and</strong> is held in place by an elastomeric drive ring (4). The drive ring causesthe rotor to turn with the shaft <strong>and</strong> provides a positive, static seal against the shaft. Since there is no metalto-metalcontact, there are no friction or wear concerns.NOTICE: The INPRO VBX is a one-piece design. Do not attempt to separate the rotor from the statorbefore or during installation. Doing so may result in equipment damage.BACA"VBX" O-ring actionBStaticCDynamic1 Rotor2 Stator3 "VBX" ring4 Rotor drive ring5 Stator gasket6 Expulsion port7 D groove8 Lube return9 Location shoulderAssemble the INPRO labyrinth oil seal1. Wrap electrical tape around the coupling end of the shaft to cover the keyway.100 Model 3796 i-FRAME <strong>Installation</strong>, <strong>Operation</strong>, <strong>and</strong> <strong>Maintenance</strong> <strong>Manual</strong>