Installation Operation and Maintenance Manual
Installation Operation and Maintenance Manual (IOM) - Goulds Pumps
Installation Operation and Maintenance Manual (IOM) - Goulds Pumps
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>Maintenance</strong> (Continued)134236A370D496253B4235. Remove the bearing housing O-ring (496).6. Remove the clamp ring screws (236A) <strong>and</strong> separate the clamp ring (253B) from the bearing housing(134).You must remove the bearings before you can remove the clamp ring from the shaft.7. Remove the bearing housing (134) <strong>and</strong> the bearings (112A <strong>and</strong> 168A) from the shaft (122).250355370H1848. Remove the inboard bearing (168A).122168A382136253B112A9. Remove the bearing locknut (136) <strong>and</strong> bearing lockwasher (382).10. Remove the outboard bearings (112A).NOTICE: Use force only on the inner race when you press bearings off the shaft. Do not use forcein situations in which you might break a part. Doing so may result in equipment damage.NOTICE:Save the bearings for inspection. Do not reuse the bearings. Doing so may result in decreasedperformance.78 Model 3796 i-FRAME <strong>Installation</strong>, <strong>Operation</strong>, <strong>and</strong> <strong>Maintenance</strong> <strong>Manual</strong>