09.08.2015 Views

Installation Operation and Maintenance Manual

Installation Operation and Maintenance Manual (IOM) - Goulds Pumps

Installation Operation and Maintenance Manual (IOM) - Goulds Pumps

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Installation</strong><strong>Installation</strong>PreinstallationPrecautionsWARNING:• When installing in a potentially explosive environment, make sure that the motor is properly certified.• You must earth (ground) all electrical equipment. This applies to the pump equipment, the driver, <strong>and</strong>any monitoring equipment. Test the earth (ground) lead to verify that it is connected correctly.Pump location guidelinesNOTICE: Supervision by an authorized ITT representative is recommended to ensure proper installation.Failure to do so may result in equipment damage or decreased performance.WARNING:Assembled units <strong>and</strong> their components are heavy. Failure to properly lift <strong>and</strong> support this equipment canresult in serious physical injury <strong>and</strong>/or equipment damage. Lift equipment only at the specifically identifiedlifting points. Lifting devices such as eyebolts, slings, <strong>and</strong> spreaders must be rated, selected, <strong>and</strong> used forthe entire load being lifted.GuidelineKeep the pump as close to the liquid source aspractically possible.Make sure that the space around the pump issufficient.If you require lifting equipment such as a hoist ortackle, make sure that there is enough space abovethe pump.Protect the unit from weather <strong>and</strong> water damagedue to rain, flooding, <strong>and</strong> freezing temperatures.Do not install <strong>and</strong> operate the equipment in closedsystems unless the system is constructed withproperly-sized safety devices <strong>and</strong> control devices.Explanation/commentThis minimizes the friction loss <strong>and</strong> keeps thesuction piping as short as possible.This facilitates ventilation, inspection, maintenance,<strong>and</strong> service.This makes it easier to properly use the liftingequipment.This is applicable if nothing else is specified.Acceptable devices:• Pressure relief valves• Compression tanks• Pressure controls• Temperature controls• Flow controlsIf the system does not include these devices, consultthe engineer or architect in charge before youoperate the pump.Take into consideration the occurrence of unwanted The best pump location for noise <strong>and</strong> vibrationnoise <strong>and</strong> vibration.absorption is on a concrete floor with subsoilunderneath.If the pump location is overhead, undertake specialprecautions to reduce possible noise transmission.Consider a consultation with a noise specialist.26 Model 3796 i-FRAME <strong>Installation</strong>, <strong>Operation</strong>, <strong>and</strong> <strong>Maintenance</strong> <strong>Manual</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!