Commissioning, Startup, <strong>Operation</strong>, <strong>and</strong> Shutdown (Continued)NOTICE:Make sure to lubricate the packing. Failure to do so may result in shortening the life of the packing <strong>and</strong> thepump.You must use an external sealing liquid under these conditions:• The pumped fluid includes abrasive particles.• The stuffing-box pressure is below atmospheric pressure when the pump is running with a suction liftor when the suction source is in a vacuum. Under these conditions, packing is not cooled <strong>and</strong>lubricated <strong>and</strong> air is drawn into pump.Conditions for application of an external liquidIf...The stuffing box pressure is above atmosphericpressure <strong>and</strong> the pumped fluid is clean.The stuffing box pressure is below atmosphericpressure or the pumped fluid is not clean.An outside source of clean compatible liquid isrequired.Then...Normal gl<strong>and</strong> leaks of 40 to 60 drops per minute isusually sufficient to lubricate <strong>and</strong> cool the packing.You do not need sealing liquid.An outside source of clean compatible liquid isrequired.You must connect the piping to the lantern ringconnection with a 40 to 60 drops-per-minute leakrate. The pressure must be 15 psi (1.01 kg/cm 2 )above the stuffing box pressure.Pump primingPump priming with the suction supply below the pump (3796)Model 3796 is self-priming <strong>and</strong> does not require a foot valve in the suction line or manual priming prior tostartup (except for the initial charge). However, in a pressurized system, the pump requires an air vent or apermanent bypass line in the discharge piping to vent the evacuated air.This illustration is an example of priming a 3796 pump in a pressurized system.3796 Priming in aPressurized System71234651. By-pass line2. Concentric reducer3. Long radius elbow4. Shutoff valve5. Strainer6. Foot valve (if used)7. Discharge isolation valveFigure 16: Priming a 3796 pumpModel 3796 i-FRAME <strong>Installation</strong>, <strong>Operation</strong>, <strong>and</strong> <strong>Maintenance</strong> <strong>Manual</strong> 59

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!