Installation Operation and Maintenance Manual
Installation Operation and Maintenance Manual (IOM) - Goulds Pumps
Installation Operation and Maintenance Manual (IOM) - Goulds Pumps
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Commissioning, Startup, <strong>Operation</strong>, <strong>and</strong> Shutdown (Continued)The annular groove in the coupling guard half must face the motor.AnnulargrooveGuard halfDriver6. Place the driver-side end plate over the motor shaft.DriverEnd plate7. Place the driver-side end plate in the annular groove of the driver-half of the coupling guard.8. Use a bolt, a nut, <strong>and</strong> two washers to secure the coupling guard half to the end plate. H<strong>and</strong>-tightenonly.The hole is located on the driver-side of the coupling guard half.9. Slide the driver-half of the coupling guard towards the motor so that the coupling guard completelycovers the shafts <strong>and</strong> coupling.Model 3796 i-FRAME <strong>Installation</strong>, <strong>Operation</strong>, <strong>and</strong> <strong>Maintenance</strong> <strong>Manual</strong> 55