Commissioning, Startup, <strong>Operation</strong>, <strong>and</strong> Shutdown (Continued)Shaft-sealing optionsIn most cases, the manufacturer seals the shaft before shipping the pump. If your pump does not have asealed shaft, see the Shaft-seal maintenance section in the <strong>Maintenance</strong> chapter.This model uses these types of shaft seals:• Cartridge mechanical seal• Conventional inside-component mechanical seal• Conventional outside-component mechanical seal• Packed-stuffing-box optionMechanical seal optionsPumps are usually shipped with mechanical seals installed. If they are not, then refer to the mechanical sealmanufacturer's installation instructions.These are the mechanical seal options for this pump:• Cartridge mechanical seal• Conventional inside component mechanical seal• Conventional outside component mechanical sealConnection of sealing liquid for mechanical sealsSeal lubrication is requiredSeal faces must have liquid film between them for proper lubrication. Locate the taps using the illustrationsshipped with the seal.Seal flushing methodsYou can use these methods in order to flush or cool the seal:MethodDescriptionProduct flushExternal flushOtherPacked stuffing box optionWARNING:Run the piping so that the pump pushes the pumped fluid from the casing <strong>and</strong>injects it into the seal gl<strong>and</strong>. If necessary, an external heat exchanger cools thepumped fluid before it enters the seal gl<strong>and</strong>.Run the piping so that the pump injects a clean, cool, compatible liquid directlyinto the seal gl<strong>and</strong>. The pressure of the flushing liquid must be 5 to 15 psi (0.35 to1.01 kg/cm 2 ) greater than the seal chamber pressure. The injection rate must be 0.5to 2 gpm (2 to 8 lpm).You can use other methods that employ multiple gl<strong>and</strong> or seal chamberconnections. Refer to the mechanical seal reference drawing <strong>and</strong> piping diagrams.Packed stuffing boxes are not allowed in an ATEX-classified environment.The factory does not install the packing, lantern ring, or split gl<strong>and</strong>.These parts are included with the pump in the box of fittings. Before you start the pump, you must installthe packing, lantern ring, <strong>and</strong> split gl<strong>and</strong> according to the Packed stuffing box maintenance section in the<strong>Maintenance</strong> chapter.Connection of sealing liquid for a packed stuffing boxWARNING:Packed stuffing boxes are not allowed in an ATEX-classified environment.58 Model 3796 i-FRAME <strong>Installation</strong>, <strong>Operation</strong>, <strong>and</strong> <strong>Maintenance</strong> <strong>Manual</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!