<strong>Maintenance</strong> (Continued)360D108496B370Bc) Install the dowel pins (469B) <strong>and</strong> bolts (370B). Tighten the bolts in a criss-cross pattern accordingto the specifications in the bolt torque values table.d) Rotate the shaft 360º to check the adapter fit.If the total indicator reading is greater than 0.005 in. (0.13 mm), then determine the cause <strong>and</strong>correct it before you proceed.7. Install the labyrinth oil-seal (333A) into the adapter (108) <strong>and</strong> the bearing frame (228).The labyrinth oil seal is an O-ring fit.8. Position the labyrinth oil-seal drain slots at the bottom (6 o’clock) position.Refer to Assemble the INPRO labyrinth oil-seal for more information on the labyrinth oil-sealinstallation.Model 3796 i-FRAME <strong>Installation</strong>, <strong>Operation</strong>, <strong>and</strong> <strong>Maintenance</strong> <strong>Manual</strong> 99