<strong>Maintenance</strong> (Continued)Bearing-housing inspectionChecklist• Inspect the bearing-housing (134) bore according to the bearing fits <strong>and</strong> tolerances table.• Replace the bearing housing if the dimensions exceed acceptable values. Reference: see Bearings fits<strong>and</strong> tolerances.• Visually inspect the bearing housing for cracks <strong>and</strong> pits.Checklist for specific modelsThis table shows bearing-housing checks that are required for specific models of pump.FrameBearing-housing checkSTi <strong>and</strong> MTiLTiEnsure that the snap-ring groove is not cracked.Clear all grooves <strong>and</strong> holes.Inspection locationsThe following images point to the areas to inspect on the bearing housing.134Figure 26: STi <strong>and</strong> MTi bearing housing134Figure 27: LTi bearing housingModel 3796 i-FRAME <strong>Installation</strong>, <strong>Operation</strong>, <strong>and</strong> <strong>Maintenance</strong> <strong>Manual</strong> 87