Job Specification<br />

For<br />

Silencer<br />

DOCUMENT No.<br />

A307-16-46-SP-6519<br />

Rev. A<br />

Page 3 of 5<br />

- ASME Section VIII Div.1.<br />

- ASME Section IX.<br />

- OSHA<br />

- ASME Sec. V<br />

- ASME Sec. II<br />

- ASME B 16.5<br />

- ASME B16.20<br />

- IBR<br />

4.0 TECHNICAL REQUIREMENTS<br />

4.1 The equipment shall be designed, manufactured, tested and supplied in accordance<br />

with the mechanical data sheets, P&IDs, process data sheets, this job specification,<br />

<strong>EIL</strong> standard specifications, applicable codes, standards and all other attachments of<br />

the material requisition.<br />

4.2 The silencer shall be designed to meet the noise level as specified in the data sheet at<br />

1-meter (perpendicular) distance from silencer discharge.<br />

4.3 The material of construction of various parts shall be as mentioned in the Mechanical<br />

data sheet.<br />

4.4 All internal acoustic insulation shall be constructed with mineral wool / fiber glass in<br />

glass cloth and shall be strengthened with stainless steel wire mesh. The insulation<br />

shall be protected with stainless steel perforated sheet of minimum 1.5mm thickness,<br />

in the path of fluid stream to reduce the noise to the desired noise level. When the<br />

insulation length is more, it shall be supported with circular rings, against sudden<br />

collapsing of the insulation due to its own weight. All internal insulation tubes, if any,<br />

shall be properly supported.<br />

During detailing, Vendor to check the suitability of acoustic Insulation material<br />

for the design temperature specified in data sheets. Incase this material is not<br />

suitable, Vendor to provide the suitable material (without cost and time implication)<br />

and backup documents for material selection to be submitted for <strong>EIL</strong> review. However<br />

guarantee of the material selection lies with Vendor.<br />

4.5 The silencer venting to atmosphere shall be provided with detachable rain hood and a<br />

bird screen at the outlet.<br />

4.6 The Silencer shall have a drain connection with a 3/4" Gate valve along with a flange<br />

and Blind Flange.<br />

4.7 Unless otherwise specified, silencer shall be designed for vertical mounting with<br />

minimum 2 Nos. support brackets.<br />

Supporting brackets & RF Pad on the silencers to be designed for the piping<br />

loads on the inlet nozzle specified in this specification.<br />

4.8 All butt welds on the silencer shall be full penetration type.<br />

4.9 Diffusers shall be seamless construction or with full radiography of butt welds.<br />

Silencers body as a minimum shall be spot radiographed.<br />

4.10 Unless otherwise mentioned, silencers shall be designed for location outside the<br />

building in the open area.<br />

Format No. <strong>EIL</strong> 1641-1924 Rev. 1<br />

Page 184 of 291<br />

Copyright <strong>EIL</strong> – All rights reserved