6.3.1 Functional <strong>Requirements</strong><br />

6.3.1.1 Interfaces<br />

Requirement No. BCISW1<br />

Name: BCI communication interface<br />

Description: External interface that communicates with other subsystems using a TCP/IP messages<br />

protocol.<br />

Reason / Comments: Easy communication <strong>and</strong> integration between subsystems.<br />

Indicative priority M<strong>and</strong>atory<br />

Requirement No. BCISW2<br />

Name: Therapist GUI<br />

Description: The graphical user interface (GUI) allows the therapist to interact with the BCI software.<br />

Reason / Comments: Facilitate the use of the BCI software to non-computer experts.<br />

Indicative priority M<strong>and</strong>atory<br />

Requirement No. BCISW3<br />

Name: Subject GUI / User GUI<br />

Description: In the training <strong>and</strong> decoding process subjects are asked to perform some tasks.<br />

Reason / Comments: The graphical user interface (GUI) displays comm<strong>and</strong>s to the subject (e.g. a visual cue<br />

indicating that the subject intends to start walking).<br />

Indicative priority M<strong>and</strong>atory<br />

6.3.1.2 Goals <strong>and</strong> expectations<br />

Requirement No. BCISW4<br />

Name: BCI software portability<br />

Description: The BCI software can run over different operating systems (Windows, Linux, etc.)<br />

Reason / Comments: The BCI software can be easily moved from an environment to another.<br />

Indicative priority Desirable<br />

6.3.1.3 Resources<br />

Requirement No. BCISW5<br />

Name: EEG sensor cap size<br />

Description: The cap is available in 3 sizes (small, medium <strong>and</strong> large); the most appropriate one needs to<br />

be chosen depending on the subject head circumference. Anyway the medium-sized cap is<br />

suitable for over 95% of all adult subjects.<br />

Reason / Comments: An appropriate cup allows achieving a better signal quality.<br />

Indicative priority Desirable<br />

Requirement No. BCISW6<br />

Name: EEG Electrodes location <strong>and</strong> number<br />

Description: The EEG electrodes are inserted via small holes in the cap. Their position on the scalp,<br />

indicated on the cap according to the extended international 10/20 system, <strong>and</strong> number<br />

depends on what brain areas are activated during a specific cognitive task. Ongoing<br />

<strong>CORBYS</strong> research will identify those (Tasks 3.3 <strong>and</strong> 3.5).<br />

Reason / Comments: Specific electrodes placements <strong>and</strong> number related to the cognitive processes required in<br />

<strong>CORBYS</strong> are needed.<br />

Indicative priority M<strong>and</strong>atory<br />

Requirement No. BCISW7<br />