BCI requires a machine free training stage before users can work the technology. The<br />

training process modifies some internal parameters that successively the decoding process<br />

uses. This procedure must be observed for each cognitive-related task is planned to be used.<br />

A training phase is also needed for the artefacts removal processing (Training artefacts).<br />

The possible values of the execution mode input are<br />

� Training motion *<br />

� Training feedback<br />

� Training attention<br />

� Training artefacts<br />

� Decoding motion<br />

� Decoding feedback<br />

� Decoding attention<br />

� Decoding motion & feedback<br />

� Decoding motion & attention<br />

� Decoding feedback & attention<br />

� Decoding motion & feedback & attention<br />

� Stop<br />

The independence of the cognitive-related tasks allows their simultaneous execution in the<br />

decoding process (i.e. Decoding motion & feedback, Decoding attention & feedback, etc.).<br />

A stop input value has been also added to allow the interruption of the running processes.<br />

*Motion, feedback <strong>and</strong> attention are the abbreviations for intention of legs motion, feedback<br />

error-related potential <strong>and</strong> attention states respectively.<br />

Reason / Comments:<br />

Indicative priority M<strong>and</strong>atory<br />

Requirement No. BCI2<br />

Name: Configuration File<br />

Description: Values of the optional parameters, a default setting is provided<br />

A list of possible optional parameters is available below:<br />

� Number of electrodes to be used.<br />

� Sampling rate of the EEG signal.<br />

� Decoders parameters.<br />

A complete list will be provided depending on the results of the ongoing <strong>CORBYS</strong> research.<br />

Reason / Comments:<br />

Indicative priority Optional<br />

Output<br />

Requirement No. BCI3<br />

Name: Raw EEG<br />

Description: Electroencephalographic signal acquired by the BCI hardware<br />

Reason / Comments:<br />

Indicative priority Optional<br />

Requirement No. BCI4<br />

Name: Filtered EEG<br />

Description: Electroencephalographic signal filtered from occurring artefacts<br />