MS-7589<br />
Solving a Mirror Conflict<br />
A Mirror conflict occurs when both disks in a RAID 1 (Mirror) configuration are unplugged<br />
from the system in turn, then plugged in again. Since both disks contain exactly<br />
the same data, the system will be unable to determine which of the two is the source<br />
drive. This option allows you to set the source drive and rebuild the Mirror drive according<br />
to the contents of the source drive.<br />
To solving a Mirror conflict:<br />
Select “Solving a Mirror Conflict” and press . In the Hard Disk Driver List menu<br />
use key to select the disks you want to set as source drive. Using the ,<br />
move to the RAID Disk Drive List menu and highlight the RAID set that you want to<br />
rebuild. Press to begin rebuilding the Mirror configuration.<br />
A status bar at the bottom of the screen shows the progress of the rebuilding.<br />
C-9