PLT

Pull Data Bank Register from Stack

PLT

Operation

Sf-S+1

DT f- M(S)

Description

The stack pointer S is incremented, and then the data bank register DT is

restored with the data at the address indicated by the stack pointer S.

Status flags

IPL : Not affected.

N Set to 1 when bit 7 of the operation result is 1. Otherwise, cleared to O.

V Not affected.

m Not affected.

x Not affected.

D Not affected.

Not affected.

Z Set to 1 when the result of operation is O. Otherwise, cleared to O.

C Not affected.

Addressing mode Syntax Machine code Bytes Cycles

Stack PLT AB16 1 6