TOB

Transfer Direct Page Register to Accumulator B

TOB

Operation

If m=O,

BL f- DPRL

BH f- DPAH

If m=1,

BL f- DPAL

Description

Loads the accumulator B with the contents of the direct page register DPA. The

contents of the direct page register DPA are not changed.

Status flags

IPL:

N

v

m

x

D

I

Z

C

Not affected.

Set to 1 when bit 15 (or bit 7 if the data length selection flag m is set to 1) of

the operation result is 1. Otherwise, cleared to O.

Not affected.

Not affected.

Not affected.

Not affected.

Not affected.

Set to 1 when the result of operation is O. Otherwise, cleared to O.

Not affected.

Addressing mode Syntax Machine code I Bytes Cycles

Implied TOB 4216, 7B16 I 2 4

152