Removal and dismantling of the steam cylinder<br />
Caution! Before commencing any dismantling work, the steam-air humidifier is to be taken out<br />
of operation as described in chapter 6.3 and rendered safe from inadvertent operation.<br />
Caution! If steam has been produced shortly before discontinuing operation, the steam cylinder<br />
will be hot. Well-insulated gloves should therefore be worn when carrying out the removal<br />
operation.<br />
1 2 3<br />
1. Release the front door locking devices using a screwdriver (rotate 90° left) and remove the front<br />
doors.<br />
2. Free the upper hose clamp of the steam hose using a screwdriver and pull the hose downward from<br />
the steam connection.<br />
3. Press snap-fastenings together, then remove the heating cable loom plug connector from the<br />
connector socket.<br />
4 5 6<br />
4. Release the clamping ring (steam cylinder fixation).<br />
5. Lift the steam cylinder carefully from the coupling bush and remove it towards the front of the unit.<br />
Caution! Set the steam cylinder down carefully.<br />
6. Loosen the steam cylinder cover clamping ring.<br />
55