E X - F L O O D L I G H T<br />

PX... for high pressure discharge lamps<br />

Metal version for Zone 1<br />

Description<br />

The explosion-protected floodlight PX...<br />

for high pressure discharge and halogen<br />

lamps are in accordance to the ATEX-<br />

Directive 94/9/EG as well as the European<br />

Norms EN 50014, EN 50018 and<br />

EN 50019. They are certified for use in the<br />

Zones 1 and 2.<br />

The light fitting housing is made of copperfree<br />

aluminium, the glass cover of a mechanical<br />

and thermal resistant borosilicate<br />

glass. All external screws are made of<br />

stainless steel.<br />

The electrical components are thermically<br />

separated in their own compartment and<br />

have a separate Ex-e maintenance-friendly<br />

connection compartment.<br />

With the adjustable mounting frame an optimum<br />

on light guidance is reached. Due to<br />

the robust architecture it has more than<br />

proven its reliability in chemical factories<br />

and offshore platforms for illuminating large<br />

areas and selective large objects.<br />

For environmental temperatures<br />

of up to + 55° C<br />

Robust light alloy housing<br />

Non-loosable screws made of<br />

stainless steel<br />

Safety Standard IP 67<br />

Ex-e connection compartment<br />

for easy installation<br />

4.22<br />

Polar 120 curve<br />

120<br />

PX 40 (HST) narrow-angle reflector<br />

90<br />

60<br />

150<br />

300<br />

450<br />

30<br />

600<br />

750<br />

30<br />

C 0<br />

0<br />

C90<br />

Rated luminous flux of lamps:<br />

approx. 90.000 lm (600 W/HST-T)<br />

approx. 55.500 lm (400 W/HST-T)<br />

approx. 33.000 lm (250 W/HST-T)<br />

approx. 17.000 lm (150 W/HST-T)<br />

approx. 35.000 lm (400 W/HIT-T)<br />

approx. 20.000 lm (250 W/HIT-T)<br />

approx. 14.000 lm (150 W/HIT-T)<br />

approx. 10.000 lm (500 W/QT)<br />

approx. 14.000 lm (500 W/HME-SB)<br />

Light fitting efficiency in operation:<br />

75 % with T (tubular lamp)<br />

50 % with B (eliptical lamp)<br />

l/cd/klm<br />

60<br />

90