30<br />

X55<br />

72<br />

72<br />

Attachement Ex 28/Ex 29<br />

x = mounting dimensions<br />

ZONE 1 ZONE 2 ZONE 21 ZONE 22<br />

E X - C O N T R O L A N D D I S T R I B U T I O N S S Y S T E M S<br />

E X - C O N T R O L A N D I N D I C A T I N G E L E M E N T S<br />

I Control swtich GHG 28 / GHG 29 I<br />

Technical data<br />

GHG 29 GHG 28<br />

Control switch GHG 28 ER, for panel mounting type GHG 249<br />

Marking to 94/9/EG II 2 G<br />

Type of protection EEx dei IIC<br />

EC-type examination certificate PTB 98 ATEX 1117 U<br />

Rated voltage to max. 690 V<br />

Rated current max. 20 A<br />

Switching capacity AC-1 690 V/20 A<br />

Switching capacity AC-3 400 V/20 A ⎮ 500 V/16 A<br />

Switching capacity AC-11 230 V/ 8 A ⎮ 500 V/ 6 A<br />

Switching capacity DC-11 24 V/ 6 A ⎮ 230 V/0,4 A<br />

with gold contact points max. 400 mA<br />

Connecting terminals 2 x 2.5 mm 2 fine wire, 6 mm 2 single wire<br />

Weight approx. 0.55 kg<br />

Technical data<br />

Control switch GHG 29, for mounting in enclosure<br />

Marking to 94/9/EG II 2 G<br />

Type of protection EEx de IIC<br />

EC-type examination certificate PTB 98 ATEX 1118 U<br />

Rated voltage to max.500 V<br />

Rated current max. 16 A<br />

for rated current ≥12 A, the cross-section of the<br />

connection cables must be ≥ 2.5 mm 2<br />

Switching capacity AC-15 230 V/6 A ⎮ 400 V/4.0 A<br />

Switching capacity DC-13 24 V/2 A ⎮ 230 V/0.5 A<br />

Design with gold contact points max. 400 mA<br />

Connecting terminals 2 x 0.5 - 2.5 mm 2 or 1 x 1.0 - 6.0 mm 2<br />

Weight 1 tier approx. 0.25 kg ⎮ 2 tiers approx. 0.40 kg<br />

3 tiers approx. 0.55 kg<br />

For coding and ordering details of control and indicating elements, see chapter 6,<br />

pages 6.72 to 6.75 or 6.100 to 6.101.<br />

Dimensions in mm CEAG SICHERHEITSTECHNIK GMBH 8.41<br />