E X - S E A R C H L I G H T<br />

SEB 8<br />

SEB 8 L ⎮ SEB 8 ADR<br />

The powerfull explosion-protected portable<br />

searchlights SEB 8 and SEB 8 L are in<br />

accordance to the ATEX-Directive 94/9/EG<br />

and have therefore been certified for usage<br />

in the Zones 1, 2, 21 and 22 in the T4 temperature<br />

class.<br />

Their use is permitted in nearly any area<br />

where the hazard of an explosive atmosphere<br />

exists. They have been developed for<br />

inspection, maintenance and repair operations<br />

in hazardous explosive atmospheres.<br />

Due to their robust construction and the<br />

high IP 65 safety standard they can be<br />

used in nearly any work area subject to high<br />

mechanical stress and high humidity.<br />

The searchlights have a light intense Halogen<br />

double bulb, a gas-tight NiCd battery<br />

4,8 V/7 Ah and a 5 LED Display.<br />

Five light emitting diodes provide continuous<br />

information on the current operating<br />

and charging state, plus it will also “warn”<br />

you in due time when the battery capacity<br />

is low or it needs to be replaced.<br />

The electronics additionally protect against<br />

excessive discharging as well as overcharging<br />

– only the amount of energy that has<br />

been used will be replaced. This increases<br />

the service life of the battery.<br />

In the event of a broken filament, the lamp<br />

will automatically switch over from the main<br />

beam to the standby light, in order to prevent<br />

the user from being left suddenly in the<br />

dark.<br />

Halogen lamp with double bulb:<br />

Luminous intensity after 4 h ≥ 15000 cd<br />

Indication of available duration<br />

provides safety of operation<br />

Broken filament and Automatic<br />

switchover to pilot light occurs<br />

No overcharging of the battery due to a<br />

recharge dependent on the capacity<br />

Focussing beam<br />

Degree of protection IP 65<br />

International Approvals<br />

1.18<br />

Range-diagram<br />

14<br />

49<br />

20<br />

57<br />

3<br />

80<br />

100 cm/Ø<br />

1 Lux<br />

150 m<br />

Indication of residual operating time<br />

100%<br />

80%<br />

60%<br />

40%<br />

20%<br />

Battery capacity<br />

Stand-by light<br />

Duration<br />

0%<br />

5.5 4.4 3.3 2.2 1.1 0 Main beam (h)<br />

25 20 15 10 5 2 0 Pilot light (h)