E X - P O L E M O U N T E D F I T T I N G S<br />

eLLM 92... 18 W - 36 W<br />

All-plastic design for Zone 1<br />

The eLLM 92 Ex-protected pole mounted<br />

light fittings for bi-pin fluorescent lamps are<br />

fitted with an electronic ballast and conform<br />

to the ATEX-Directive 94/9/EG.<br />

The eLLM 92 pole mounted light fitting<br />

combines the assets of the eLLK 92 series<br />

with a new cost-saving connecting technique.<br />

The terminal compartment complete<br />

with 44 mm diameter pole socket forms an<br />

integral part of the polyester light fitting<br />

housing.<br />

To install the light fitting, only the cover<br />

of the large terminal compartment needs to<br />

be opened, the light fitting housing remains<br />

closed. The accessory kit allows a singlesided<br />

through-wiring.<br />

Modern economical ballasts in combination<br />

with bi-pin fluorescent lamps contribute to<br />

give a 30% higher light output compared to<br />

a conventional Fa6 fluorescent lamp. The<br />

high input voltage range allows international<br />

use. Due to the standard dual channel architecture<br />

(with double lamp fittings) if one<br />

fluorescent lamp fails, the other fluorescent<br />

lamp will independently stay in operation.<br />

Double-sided lock with 10 or 20 latch<br />

points allows the protective bowl to be hingeable<br />

on both sides meaning the fitting<br />

can be mounted without having to pay attention<br />

to which side is the right side.<br />

Automatic switch built as a safety disconnector<br />

according to EN 60947-1 (IEC 664)<br />

with an automatic switch ensuring the disconnection<br />

of all exposed components<br />

when the fitting is opened.<br />

A wind load test according to VDE (EN 60<br />

598-2-3: 1989) was carried out and was<br />

passed at light spot levels of up to 8 m,<br />

15 m and above 15 meters<br />

Standard dual channel ballast<br />

Double-sided safety lock<br />

Safety locking system due<br />

to an integrated forced isolating switch<br />

Safety standard IP 66<br />

Large terminal compartment<br />

in the pole socket, now also<br />

for through-wiring<br />

International Approvals<br />

2.14<br />

Polar curve<br />

eLLM 92018/18 ⎮ eLLM 92036/36<br />

90<br />

75<br />

60<br />

45<br />

40<br />

80<br />

120<br />

160<br />

30<br />

30<br />

15 200<br />

0<br />

15<br />

C 0<br />

C90 l/cd/klm<br />

Rated luminous flux of lamps:<br />

2 x 18 W = 2700 lm ⎮ 2 x 36 W = 6700 lm<br />

Light efficiency in operation:<br />

2 x 18 W = 78 % ⎮ 2 x 36 W = 78 %<br />

45<br />

60<br />

90<br />

75