29.03.2013 Views

catalogue 3 1 0 explosionprotectedpro ducts

catalogue 3 1 0 explosionprotectedpro ducts

catalogue 3 1 0 explosionprotectedpro ducts

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Type 1<br />

Type 2<br />

Type 3<br />

271<br />

544<br />

817<br />

Direct circuit<br />

K1<br />

F1.1<br />

Dimensions in mm<br />

271<br />

271<br />

271<br />

1 3 5<br />

2 4 6<br />

L1L2L3 N PE 1 2 3 PE<br />

2A/250 V F1<br />

95 F1.1<br />

96 98<br />

0<br />

13<br />

I K1<br />

14<br />

K1<br />

ZONE 1 ZONE 2 ZONE 21 ZONE 22<br />

E X - C O N T R O L A N D D I S T R I B U T I O N S S Y S T E M S<br />

EX-STANDARD-MOTOR STARTERS MOULDED PLASTIC<br />

I Complete motor starter distributions I<br />

Technical data<br />

Complete motor starter distributions<br />

Marking to 94/9/EC II 2 G ⎮ II 2 D T80 °C/135 °C<br />

EXKO 208900 A<br />

Type of protection EEx ed IIC T4 / T6 dep. on built-on apparatus<br />

EC-Type Examination Certificate PTB 99 ATEX 1044<br />

Degree of protection EN 60529 IP 66<br />

Rated voltage 690 V AC<br />

Rated current max. 180 A<br />

Terminal cross section up to 240 mm 2<br />

Enclosure material Polyester, reinforced with glass fibre (GRP)<br />

Ordering details direct on-line starters<br />

Type Motorcapacity Cable entry Order No.<br />

to AC 3<br />

1 4 kW 3 x M25 EXKO 208 900 A0001<br />

2 5.5 kW 3 x M25 EXKO 208 900 A0002<br />

2 7.5 kW 3 x M25 EXKO 208 900 A0003<br />

Ordering details reversing starters<br />

Type Motorcapacity Cable entry Order No.<br />

to AC 3<br />

2 4 kW 3 x M25 EXKO 208 900 B0001<br />

2 5.5 kW 3 x M25 EXKO 208 900 B0002<br />

2 7.5 kW 3 x M25 EXKO 208 900 B0003<br />

Ordering details star-delta starters<br />

Type Motorcapacity Cable entry Order No.<br />

to AC 3<br />

EXKO 208900 C<br />

2 4 kW 4 x M25 EXKO 208 900 C0001<br />

2 5.5 kW 4 x M25 EXKO 208 900 C0002<br />

2 7.5 kW 4 x M25 EXKO 208 900 C0003<br />

3 11 kW 1 x M25 + 3 x M25 EXKO 208 900 C0004<br />

The motor starters are completely wired for connection by customer (see below).<br />

Reversing circuit<br />

K1 1 3 5<br />

2 4 6<br />

F1.1<br />

L1L2L3 N PE 1 2 3 PE<br />

K2 1 3 5<br />

2 4 6<br />

F1 2A/250 V<br />

95 F1.1<br />

96 98<br />

0<br />

13<br />

II<br />

K2<br />

14<br />

I<br />

K2 21<br />

22<br />

13<br />

K1<br />

14<br />

K1<br />

K1 K2<br />

21<br />

22<br />

Q1<br />

F1<br />

Star-delta starter<br />

F2<br />

95 F1.1<br />

96 98<br />

K1 1 3 5 K3 1 3 5 0<br />

2 4 6<br />

2 4 6<br />

K1 1 3 5<br />

2 4 6<br />

I<br />

15<br />

16 18<br />

23<br />

K2<br />

24<br />

K3<br />

K1<br />

21<br />

22<br />

K1<br />

K3<br />

21<br />

F1.1 K4<br />

13<br />

K3<br />

14<br />

22<br />

L1L2L3 N PE U V W Z X Y<br />

CEAG SICHERHEITSTECHNIK GMBH 8.9<br />

13<br />

K2<br />

14<br />

13<br />

K1<br />

14<br />

K3<br />

K2 K4<br />

31<br />

32<br />

8.9<br />

1<br />

2<br />

3<br />

4<br />

5<br />

6<br />

7<br />

8<br />

9

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!