29.03.2013 Views

catalogue 3 1 0 explosionprotectedpro ducts

catalogue 3 1 0 explosionprotectedpro ducts

catalogue 3 1 0 explosionprotectedpro ducts

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

1760<br />

ap.280<br />

ap.<br />

46 M25<br />

ap.340<br />

Ceiling cut-out<br />

1710+6<br />

315+3<br />

Thickness of<br />

the ceiling<br />

max. 90<br />

min.25<br />

eLLB 20058/58<br />

700 M8,15 deep<br />

M6<br />

ap.120<br />

ap.<br />

30°<br />

approx.<br />

ap.115<br />

85<br />

1700<br />

ZONE 1 ZONE 2 ZONE 21 ZONE 22<br />

E X - F L U O R E S C E N T L I G H T F I T T I N G S<br />

Technical data<br />

eLLB 20058/58<br />

EX-RECESSED CEILING LIGHT FITTINGS<br />

I eLLB 20058/58 I<br />

Marking to 94/9/EC II 2 G ⎮ II 2 D T80 °C<br />

2 x 58 W<br />

Type of protection EEx ed IIC T4 ⎮ EEx ed ib IIC T4 (CG-variant)<br />

EC-Type Examination Certificate DMT 02 ATEX E 069<br />

Enclosure material painted steel sheet, white optional polished stainles steel<br />

Cover disc single-safety glass pane of 6 mm thick<br />

Ceiling thickness min. 25 mm bis max. 90 min.<br />

Rated voltage AC: 220-254 V ± 10 %, 47-63 Hz ⎮ DC: 220-230 V ± 10 %<br />

Rated voltage CG-variant AC: 220-254 V ± 10 %, 47-63 Hz ⎮ DC: 220 V + 25 % – 20 %<br />

Circuit EVG resp. EVG + CG<br />

Rated current 0.53 A resp. 0.54 A (CG-variant)<br />

Power factor cos ϕ ≥ 0.95<br />

Degree of protection to EN 60529 IP 66<br />

Protection class I<br />

Permissible ambient temperature – 20 °C to + 50 °C<br />

Cable entries 2 x EEx e-cable entries M25 x 1.5 (plastic)<br />

for cables from Ø 8 - 17 mm ⎮ 1 x EEx e-blanking plug<br />

2 x threaded plugs M25 x 1.5<br />

Connecting terminals L1, L2, L3, L, N, PE; max. 2 x 6 mm 2 single wire per terminal<br />

Lamps Bi-pin lamp: 58 W, socket G13, see accessories<br />

Weight approx. 26 kg ⎮ approx. 27.8 kg (CG-variant)<br />

Ordering details<br />

Type Terminals Through wiring Order No.<br />

double-ended<br />

eLLB 20058/58 (2 x 58 W)<br />

2/6-2 2 x 6 x 1 2190 258 001<br />

2/6-2M1) 2 x 6 x 1 2190 258 101<br />

eLLB 20058/58 CG2) (2 x 58 W)<br />

2/6-2 2 x 6 x 1 2190 258 003<br />

2/6-2M1) 2 x 6 x 1 2190 258 103<br />

Optional: polished stainless steel design<br />

1) M: with 4 metal threads, without cable entries<br />

2) Design single monitored emergency light fitting for use in CEAG Emergency light supply unit<br />

Scope of delivery without lamp and fixing accessories.<br />

See fixing materials and accessories for light fittings on page 2.42.<br />